超宽带和高灭绝率的偏振分离器基于三度渐变的定向合器
Hamed Faramarzi1, Afsoun Soltani1, Zaker Hossein Firouzeh2
1Department of Electrical and Computer Engineering, Isfahan University of Technology, Isfahan, 8415683111, Iran.
Scientific reports
|July 18, 2024
概括
这项研究引入了一种新型的极化分离器 (PS),采用三曲线定向合器 (DC). 该设备在TE和TM两种极化模式下实现了高灭率和低插入损失.
科学领域:
- 光子学和光学工程的工程.
- 集成光学 集成光学 集成光学
- 半导体设备 半导体设备
背景情况:
- 极化分离器是光子集成电路中的关键组件.
- 对于先进的光学系统,需要高效和紧的偏振分离器.
- 光子学为小型化和具有成本效益的光学设备提供了一个平台.
研究的目的:
- 设计和数值研究一种新的极化分离器 (PS).
- 为了提高性能,使用三曲面定向合器 (DC).
- 评估设备的性能指标,包括灭绝比率,插入损失和带宽.
主要方法:
- 极化分离器设计的数值研究.
- 采用三曲线定向合器 (DC) 的实现.
- 在1550nm波长的性能特征.
主要成果:
- 拟议的PS的灭绝比为35.7dB (TE) 和37.35dB (TM).
- 插入损失低于0.58dB (TE) 和0.4dB (TM). 插入损失低于0.58dB (TE) 和0.4dB (TM).
- 该设备显示ER>20dB的带宽为170nm,ER>25dB的带宽为136nm.
结论:
- 设计的两极分离器表现出色的性能.
- 三度渐变直流方法对于高性能PS设备是有效的.
- 该设备适用于需要在光子学中高效偏振管理的应用.
相关概念视频
¹³C NMR: ¹H–¹³C Decoupling
The probability of having two carbon-13 atoms next to each other is negligible because of the low natural abundance of carbon-13. Consequently, peak splitting due to carbon-carbon spin-spin coupling is not observed in spectra. However, protons up to three sigma bonds away split the carbon signal according to the n+1 rule, resulting in complicated spectra.
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
Mass Analyzers: Common Types
The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
Tandem Mass Spectrometry
Tandem mass spectrometry is a technique that uses multiple mass analyzers in series to obtain a higher selectivity and reduce chemical noise during analyte detection. Instruments with multiple analyzers separated by an interaction cell enable secondary fragmentation and selected study of the fragment ions.Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called...
High-Performance Liquid Chromatography: Types of Detectors
The role of the detectors in High-Performance Liquid Chromatography (HPLC) is to analyze the solutes as they exit from the chromatographic column. The detector recognizes the solute's property and generates corresponding electrical signals, which are converted into a readable graph of the detector's response versus elution time called a chromatogram at the computer. There are several types of HPLC detectors, each with its own advantages and limitations, depending on the analyte properties and...
Double Resonance Techniques: Overview
Double resonance techniques in Nuclear Magnetic Resonance (NMR) spectroscopy involve the simultaneous application of two different frequencies or radiofrequency pulses to manipulate and observe two distinct nuclear spins. One important application of double resonance is spin decoupling, which selectively suppresses coupling with one type of nucleus while observing the NMR signal from another nucleus, simplifying the spectrum and enhancing resolution.
Spin decoupling is usually achieved by...
Spin decoupling is usually achieved by...
Line Protection with Impedance Relays
Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
Under normal conditions, low load currents keep the measured...


