相关实验视频
Updated: Jun 20, 2025

07:06
Binocular Dynamic Visual Acuity in Eyeglass-Corrected Myopic Patients
Published on: March 29, 2022
2.5K
患有不同程度近视的患者的眼睛表面
Yan-Yun Lyu1, Shuang Wang2, Xiao-Niao Chen3
1Tongren Eye Care Center, Beijing Tongren Hospital, Capital Medical University, Beijing 100730, China.
International journal of ophthalmology
|July 19, 2024
概括
近视的轴长度延长会增加干眼的发生率和严重程度. 较长的轴长度与更严重的干眼症状和眼睛表面变化相关,影响膜稳定性.
科学领域:
- 眼科医生 眼科 眼科
- 视光学测量 视光学测量 视光学测量
- 眼睛表面疾病 眼睛表面疾病
背景情况:
- 近视是一种普遍的折射误差.
- 眼睛表面的健康对于视觉舒适至关重要.
- 近视严重程度和干眼之间的关系尚未完全理解.
研究的目的:
- 为了研究不同程度近视的患者眼睛表面的临床特征.
- 为了确定轴长度和干眼参数之间的关联.
主要方法:
- 一项对122名近视参与者的横截面研究.
- 收集了关于折射,生物识别参数和眼睛表面参数的数据.
- 使用的眼皮表面疾病指数 (OSDI) 评分,眼膜分解时间 (BUT),角膜光素染色 (CFS) 和希尔默I测试 (SIT).
主要成果:
- 增加的轴长 (AL) 与较高的干眼发病率和严重程度相关.
- 较长的AL与眼膜分解时间 (BUT) 的减少和角膜光素染色 (CFS) 点的增加有关.
- OSDI分数,BUT和SIT结果显示了与AL,球形等效 (SE) 和角膜形 (AST) 有显著的相关性.
结论:
- 轴长度延长是近视患者干眼的重要危险因素.
- 较大的轴长会导致更严重的干眼,其特点是增加CFS和膜不稳定性.
- 球体等效和角膜形与干眼症状和眼睛表面参数负相关.
相关概念视频
Focusing of Light in the Eye
2.7K
Light rays enter the eye through the cornea, a transparent dome-shaped tissue that is the eye's outermost layer. The cornea bends or refracts, light rays traveling to the pupil. The shape of the cornea determines how much of the light is bent and whether the image will be focused correctly on the retina at the back of the eye. Once the light has passed through both refraction layers, it converges into a single focal point onto a small area. This is where photoreceptors start transforming...
2.7K
Glaucoma: Overview
536
Glaucoma is an eye condition characterized by increased intraocular pressure that damages the retina and optic nerve, leading to irreversible blindness if left untreated. The human eye has various components, including the cornea, iris, pupil, lens, and optic nerve. Aqueous humor is secreted by the epithelium of the ciliary body in the posterior chamber and flows through the trabecular meshwork and canal of Schlemm, maintaining normal intraocular pressure. The trabecular meshwork and the canal...
536
Open Angle Glaucoma: Treatment
422
In open-angle glaucoma, the iridocorneal angle remains open, but the trabecular meshwork becomes stiff, slowing down the outflow of aqueous humor. This causes a buildup of aqueous humor in the anterior chamber, leading to a sudden increase in intraocular pressure. The treatment for open-angle glaucoma focuses on reducing the elevated intraocular pressure by either decreasing the secretion of aqueous humor or increasing its outflow.
Drugs such as carbonic anhydrase inhibitors, α2- and...
Drugs such as carbonic anhydrase inhibitors, α2- and...
422
Accessory Structures of the Eye
1.5K
Optical perception, or vision, is an extraordinary sense dependent on converting light signals received via the ocular organs. These organs, known as eyes, are securely positioned within the bony cavities of the skull, called orbits. The orbits serve a dual purpose: a protective shield for the ocular globes and a stable attachment point for the soft ocular tissues. The eye's external protective mechanisms include the eyelids, which are edged with lashes that act as a barrier against foreign...
1.5K
Angle Closure Glaucoma: Treatment
468
Angle-closure glaucoma, or closed-angle glaucoma, is an eye condition where the iris bulges out and blocks the iridocorneal angle, resulting in a buildup of aqueous humor and increased intraocular pressure. Immediate medical attention is necessary due to the sudden onset of symptoms. The treatment for angle-closure glaucoma includes short-term and long-term approaches. Short-term treatment involves using eye drops like pilocarpine to lower intraocular pressure by increasing aqueous humor...
468
Imaging Biological Samples with Optical Microscopy
4.7K
Optical microscopy uses optic principles to provide detailed images of samples. Antonie van Leeuwenhoek designed the first compound optical microscope in the 17th century to visualize blood cells, bacteria, and yeast cells. In 1830, Joseph Jackson Lister created an essentially modern light microscope. The 20th century saw the development of microscopes with enhanced magnification and resolution.
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
4.7K