对于微电网不平衡运行的干扰拒绝控制:不变量设置方法
Hilmy Awad1, Hisham M Soliman2, Ehab H E Bayoumi3
1Department of Electrical Technology, Faculty of Technology and Education, Helwan University, Cairo, Egypt.
ISA transactions
|July 19, 2024
概括
这项研究引入了一种新的追踪器设计,以减轻微电网中的电压不平衡. 该方法有效地减少了负序列影响,提高了电源质量和干扰期间的系统稳定性.
科学领域:
- 电气工程 电气工程
- 电力系统 电力系统
背景情况:
- 电压失衡显著降低了微电网中的电力质量.
- 控制电压不平衡对于可靠的微电网运行至关重要.
研究的目的:
- 提出一种新的追踪器设计,以减轻微电网中的电压不平衡.
- 为了减轻负序列组件的影响,将其视为边界干扰.
- 在不平衡条件下确保稳定性和提高电力质量.
主要方法:
- 开发了一种包含正负序列组件的微电网模型.
- 基于吸引圆集和不变集原理的控制策略被设计出来.
- 在跟踪器合成中使用了H∞方法,以最大限度地减少圆体积.
- 用规范局限的不确定性来建模外部干扰.
主要成果:
- 拟议的追踪器有效地减轻了电压不平衡和负序列效应.
- 与标准的H∞方法相比,模拟显示出更高的精度和动态响应.
- 在各种不平衡的场景和故障下,控制策略被证明是有效的.
结论:
- 开发的追踪器设计为微电网中的电压不平衡控制提供了强大的解决方案.
- 恒量集和H∞方法在准确性和动态响应方面提供了增强的性能.
- 这种方法显著提高了微电网电力质量和运行稳定性.
相关概念视频
Multimachine Stability
150
Multimachine stability analysis is crucial for understanding the dynamics and stability of power systems with multiple synchronous machines. The objective is to solve the swing equations for a network of M machines connected to an N-bus power system.
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
150
Reclosers and Fuses
100
Automatic circuit reclosers enhance the protection of distribution circuits by interrupting and auto-reclosing an AC circuit according to a preset sequence. They effectively manage temporary faults on overhead distribution lines, often caused by tree limbs or wildlife, by briefly disrupting service to improve overall reliability. However, contact with reclosers or energized broken conductors on the ground can pose serious hazards.
A comprehensive protection scheme for radial distribution...
A comprehensive protection scheme for radial distribution...
100
Load-frequency control
147
Load-frequency control (LFC) is vital for maintaining power system stability, ensuring that frequency and power flows remain within acceptable limits during load changes. Turbine-governor control eliminates rotor accelerations and decelerations following load changes. However, a steady-state frequency error persists when the change in the turbine-governor reference setting is zero. In an interconnected power system, each area agrees to export or import a scheduled amount of power through...
147
Routh-Hurwitz Criterion I
218
Consider an electrical power grid, where stability is essential to prevent blackouts. The Routh-Hurwitz criterion is a valuable tool for assessing system stability under varying load conditions or faults. By analyzing the closed-loop transfer function, the Routh-Hurwitz criterion helps determine whether the system remains stable.
To apply the Routh-Hurwitz criterion, a Routh table is constructed. The table's rows are labeled with powers of the complex frequency variable s, starting from the...
To apply the Routh-Hurwitz criterion, a Routh table is constructed. The table's rows are labeled with powers of the complex frequency variable s, starting from the...
218
Control of Power Flow
262
There are several methods to control power flow in power systems:
262
Radial System Protection
94
Radial systems employ time-delay overcurrent relays to reduce load interruptions. When a fault occurs, the nearest breaker opens first, while upstream breakers remain closed due to longer delay settings. This approach ensures minimal disruption to the rest of the system.
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
94