FireSync EMS:一种用于燃烧表面积计算的新型移动应用程序
Nicolas Malkoff1, Brigette Cannata1, Sarah Wang1
1Keck School of Medicine, University of Southern California, Los Angeles, CA 90033, USA.
概括
一个新的移动应用程序,FireSync EMS,提供了一个更准确和用户友好的方法来计算与传统的隆德-布罗德图表相比,燃烧的百分比总体表面积 (TBSA),特别是对于儿科烧伤.
科学领域:
- 紧急医疗 紧急医疗
- 燃烧管理 燃烧管理
- 医疗技术 医疗技术 医学技术
背景情况:
- 准确估计燃烧的百分比总体表面积 (TBSA) 对患者的护理和预后至关重要.
- 隆德-布罗德 (LB) 图表是当前的标准,但在现场使用时可能很复杂.
- 应急人员需要实用工具来快速评估燃烧情况.
研究的目的:
- 开发和验证一个新的移动应用程序,FireSync EMS,用于估计TBSA燃烧.
- 将FireSync EMS的准确性和可用性与LB图表进行比较.
- 评估用户体验,玩具尺寸和烧伤尺寸对估计准确性的影响.
主要方法:
- 开发了FireSync EMS移动应用程序.
- 模拟了婴儿,儿科和成人人形上不同大小的8种烧伤.
- 用FireSync EMS和LB图表对42名医学学生和消防员的TBSA估计进行比较.
- 统计分析包括单变量分析和混合效应线性回归.
主要成果:
- 与LB图表相比,FireSync EMS显著降低了高估偏差 (0.11%与0.91%,P = .002).与LB图表相比,FireSync EMS显著降低了高估偏差 (0.11%与0.91%,P = .002).
- 该应用程序对儿童尺寸的模型和烧伤<10%或>20%的TBSA表现出了特别的准确性.
- LB图表是估计误差的独立决定因素 (1.19x乘法效应与FireSync EMS相比,P < .001).
- 用户发现FireSync EMS显著更容易,更直观,更快,更可取.
结论:
- 与LB图表相比,FireSync EMS提供了比LB图表更准确,更少偏见的TBSA燃烧估计.
- 移动应用程序是第一响应者在烧伤评估中的实用和首选工具.
- FireSync EMS有可能改善烧伤患者的初始管理和结果.
相关概念视频
Ultrasound II: Endoscopic Ultrasound and FibroScan
89
Endoscopic Ultrasound (EUS) and FibroScan are valuable diagnostic tools in gastroenterology and hepatology, each with specific applications and techniques.
Endoscopic Ultrasound (EUS):
Endoscopic Ultrasound (EUS):
89
Burn Injuries
2.4K
Burn injuries occur when the skin and underlying tissues are damaged due to exposure to heat, electricity, chemicals, radiation, or friction. They can vary in severity, from minor superficial burns to severe deep burns that can be life-threatening.
The damage results in the death of skin cells, which can lead to a massive loss of fluid. Dehydration, electrolyte imbalance, and renal and circulatory failure follow, which can be fatal. Burn patients are treated with intravenous fluids to offset...
The damage results in the death of skin cells, which can lead to a massive loss of fluid. Dehydration, electrolyte imbalance, and renal and circulatory failure follow, which can be fatal. Burn patients are treated with intravenous fluids to offset...
2.4K