分布式光伏电力的短期间歇性评估
Yili Ma1, Yi Huang1, Yue Yuan1
1School of Electrical and Power Engineering, Hohai University, Nanjing, Jiangsu Province, China.
Heliyon
|July 23, 2024
概括
本研究引入了一种新的方法来评估分布式光伏功率的间歇性,使用一般化极端价值理论. 它解决了小样本数据中的挑战,帮助储能规划和电网稳定.
科学领域:
- 电气工程 电气工程
- 电力系统 电力系统
- 可再生能源可再生能源是可再生能源.
背景情况:
- 分布式光伏 (PV) 电力为电力系统运行带来了重大不确定性.
- 间歇性对电网稳定性构成了比简单的功率波动更大的挑战.
研究的目的:
- 开发一种可靠的方法来评估分布式光伏电力的间歇性,特别是对于罕见但具有影响力的事件.
- 为储能配置和项目开发决策提供数据驱动的支持.
主要方法:
- 利用通用极值 (GEV) 理论来解决"小样本大差距"间歇性事件.
- 建立的概率评估指数:T小时周期突变强度和频率.
- 开发了间歇性元素的二维联合概率分布.
主要成果:
- 在光伏间歇性领域引入了回报期和回报水平概念.
- 启用数据支持,以确定储能能力,持续时间和项目时间表.
- 证明了一种与小样本大小和工程应用相兼容的方法.
结论:
- 提出的基于GEV的方法有效评估光伏功率间歇性,即使数据有限.
- 概率指数和联合分发增强了对电网运营的风险评估.
- 这种方法支持信息化决策,用于整合分布式光伏,并确保电力系统的稳定性.
更多相关视频
相关概念视频
Instantaneous Power
368
Instantaneous power is important in electrical circuits, mainly when dealing with sinusoidal input. Instantaneous power, denoted as p(t), results from the multiplication of the instantaneous voltage (v(t)) across an element and the instantaneous current (i(t)) flowing through it. This relationship adheres to the passive sign convention and represents a fundamental principle in electrical engineering.
368
Power System Three-Phase Short Circuits
79
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
79
Fast Decoupled and DC Powerflow
182
The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
182
Power in a Three-Phase Circuit
307
Three-phase systems have two configurations: the wye and delta. A star configuration can be three or four wires; in a delta configuration, the components are connected in a closed loop. Instantaneous power refers to the power value at a precise moment, and in a balanced three-phase system, it is constant. This is because the sum of the instantaneous powers in the three phases remains steady over time, despite individual fluctuations, due to the symmetry and phase relationship. The total...
307
Maximum Power Flow and Line Loadability
106
The maximum power flow for lossy transmission lines is derived using ABCD parameters in phasor form. These parameters create a matrix relationship between the sending-end and receiving-end voltages and currents, allowing the determination of the receiving-end current. This relationship facilitates calculating the complex power delivered to the receiving end, from which real and reactive power components are derived.
106
Distribution Reliability and Automation
107
Distribution reliability in electrical power systems is critical for ensuring an uninterrupted power supply to consumers at minimal cost. According to IEEE Standard Terms, reliability is the probability that a device will function without failure over a specified time period or amount of usage. For electric power distribution, this translates to maintaining continuous power supply and addressing customer concerns over power outages. Several indices, as defined by IEEE Standard 1366-2012, are...
107