变压器特征提取和评估方法 地铁流浪电流引起的直流偏差
Aimin Wang1, Sheng Lin2, Guoxing Wu3
1School of Electrical Engineering and Electronic Information, Xihua University, Chengdu 610039, China.
Entropy (Basel, Switzerland)
|July 26, 2024
概括
地铁流浪电流可能会导致变压器直流偏差. 本研究提出了一种使用变压器中性的直流和振动信号来评估这种风险的新方法,改进了传统方法.
科学领域:
- 电气工程 电气工程
- 电力系统分析 分析 分析
- 变压器健康监测 变压器健康监测
背景情况:
- 地铁流浪电流可以导致变压器中的直流偏差.
- 中性直流水平波动,使它们成为 DC 偏差风险的不可靠的唯一指标.
- 现有的方法可能缺乏对变压器直流偏差风险的全面评估.
研究的目的:
- 开发统一的方法来提取和评估从地铁流浪电流中变压器直流偏差风险.
- 整合变压器中性的直流和振动信号,以进行更强大的风险评估.
- 建立一个客观的评估模型,避免人工经验偏见.
主要方法:
- 通过比较直流和振动信号的大小和频率分布来提取特征.
- 相关性分析和聚类,以确定关键特征指标.
- 对客观指标权重的权方法 (EWM) 的应用.
- 使用现实世界的变压器中性直流和振动数据进行验证.
主要成果:
- 成功地从组合的直流和振动信号中提取了特征指标.
- 使用拟议的方法证明了评估变压器直流偏差风险的可行性.
- 权方法为风险评估提供了客观的权重.
结论:
- 拟议的统一特征提取和评估方法有效地评估了由地铁流浪电流引起的变压器直流偏差风险.
- 将中性直流和振动信号结合在一起,为风险评估提供了更可靠的方法.
- 开发的模型为变压器监控提供了一个客观和数据驱动的解决方案.
更多相关视频
00:10X-ray Beam Induced Current Measurements for Multi-Modal X-ray Microscopy of Solar Cells
Published on: August 20, 2019
13.8K
06:45Design and Application of a Fault Detection Method Based on Adaptive Filters and Rotational Speed Estimation for an Electro-Hydrostatic Actuator
Published on: October 28, 2022
1.6K
相关概念视频
Equivalent Circuits for Practical Transformers
407
The practical equivalent circuits of single-phase two-winding transformers exhibit significant deviations from their idealized versions due to the inherent properties of winding resistance and finite core permeability. These properties result in real and reactive power losses, affecting the transformer's performance. Understanding these deviations is crucial for designing more efficient transformers.
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
407
Energy Losses in Transformers
857
In an ideal transformer, it is assumed that there are no energy losses, and, hence, all the power at the primary winding is transferred to the secondary winding. However, in reality, the transformers always have some energy losses, and, hence, the output power obtained at the secondary winding is less than the input power at the primary winding due to energy losses.
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
857
Differential Relays
125
Differential relays are used to protect generators, buses, and transformers by comparing electrical quantities at different points. When a fault occurs, the difference in current between the two points triggers the relay to operate, opening the circuit breaker. Under normal conditions, the current entering (i1) and leaving (i2) a generator are equal. When a fault occurs, however, these currents become unequal, and the difference current flows in the relay operating coil, causing the relay to...
125
Power System Three-Phase Short Circuits
79
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
79
Three-Phase Short Circuit—Unloaded Synchronous Machine
133
Conducting a three-phase short circuit test on an unloaded synchronous machine helps understand its impact on the system. The AC fault current's oscillogram, with the DC offset removed, reveals that the waveform amplitude decreases from an initially high value to a steady-state level for one phase of the machine.
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
133
Series R—L Circuit Transients
95
In a series resistor-inductor (R-L) circuit, closing the switch at the start of the time period simulates a three-phase short circuit, a fault condition where all three phases of an unloaded synchronous machine are short-circuited. When there is no fault impedance and no initial current, the initial voltage is determined by the phase angle of the source voltage.
Using Kirchhoff's Voltage Law (KVL) to analyze this circuit helps determine the total asymmetrical fault current, which consists...
Using Kirchhoff's Voltage Law (KVL) to analyze this circuit helps determine the total asymmetrical fault current, which consists...
95