Pd层厚度对Pd涂层Cu线的粘合可靠性的影响
Junling Fan1, Donglin Yuan1, Juan Du1
1School of Chemical and Environmental Engineering, Jiaozuo University, Jiaozuo 454000, China.
Micromachines
|July 27, 2024
概括
铜 (Cu) 线上较厚的 (Pd) 层提高了粘合可靠性. 增加Pd厚度提高了高温储存后的粘合强度,并降低了热循环中的故障率,表明了优越的环境抗性和稳定性.
科学领域:
- 材料科学 材料科学 材料科学
- 表面工程是什么?表面工程是什么?
- 可靠性工程可靠性工程
背景情况:
- 在电子包装中,粘合可靠性至关重要.
- 涂铜 (PCC) 线用于各种电子互连.
- 了解Pd层厚度对键完整性的影响至关重要.
研究的目的:
- 为了研究 (Pd) 层厚度对Pd涂层Cu (PCC) 线束的可靠性的影响.
- 在高温储存之前和之后评估结合性能.
- 为了确定最佳的Pd层厚度,以提高结合稳定性.
主要方法:
- 使用具有不同Pd层厚度的PCC线材制造粘合样本.
- 评估结合参数 (压力,超声波功率) 对结合形成的影响.
- 结合样品的高温储存和冷热循环测试.
- 对键强度,故障模式和金属间化合物 (IMC) 增长的分析.
主要成果:
- 粘合参数显著影响粘合质量;低于最佳的设置导致不充分的变形或损伤.
- 高温储存促进了Cu-Ag金属间化合物 (IMC) 的生长,最初增加了键强度.
- 较厚的Pd层在高温储存后表现出更高的结合强度,在热循环中故障率更低.
- 在较薄的Pd层中,IMC过度增长会导致Kirkendall毛孔和随着时间的推移而降低的剪切力.
结论:
- 在PCC电线上,Pd层的厚度是结合可靠性的关键因素.
- 较厚的Pd层提供了对环境压力,如高温和热循环的优越抵抗力.
- 优化Pd层厚度可以提高电子互连的长期稳定性和整体可靠性.
更多相关视频
10:28Sensitivity Enhancement of Soft Capacitive Pressure Sensors Using a Solvent Evaporation-Based Porosity Control Technique
Published on: March 24, 2023
1.1K
08:50Fabrication and Characterization of a Conformal Skin-like Electronic System for Quantitative, Cutaneous Wound Management
Published on: September 2, 2015
8.8K
相关概念视频
Thermal expansion and Thermal stress: Problem Solving
1.1K
San Francisco's Golden Gate Bridge is exposed to temperatures ranging from -15 °C to 40 °C. At its coldest, the main span of the bridge is 1275 m long. Assuming that the bridge is made entirely of steel, what is the change in its length between these temperatures?
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in...
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in...
1.1K
Electrodeposition
616
Electrodeposition is a technique used to separate an analyte from interferents by electrochemical processes. Here, the analyte is a metal ion that can be deposited on an electrode immersed in the sample solution. The electrochemical setup consists of an anode and a cathode. When an electric current is applied to the setup, oxidation occurs at the anode. At the cathode, which consists of a large metal surface, metal ions undergo reduction and deposit onto the surface.
Electrodeposition can...
Electrodeposition can...
616
Bonding in Metals
47.1K
Metallic bonds are formed between two metal atoms. A simplified model to describe metallic bonding has been developed by Paul Drüde called the “Electron Sea Model”.
47.1K