湿衣热电阻测量 热电阻测量
Gianluca Crotti1, Roberto Cantù1, Stefano Malavasi1
1Dipartimento di Ingegneria Civile e Ambientale (DICA), Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milano, Italy.
Sensors (Basel, Switzerland)
|July 27, 2024
概括
研究人员比较了测量湿衣热电阻的两种方法. 一种新的,简化过渡方法为评估湿衣绝缘提供了一种有效且更容易的替代传统静止方法.
科学领域:
- 材料科学 材料科学 材料科学
- 热力工程是热力工程中的一个.
- 运动技术技术 运动技术
背景情况:
- 在海上运动中,对可靠的湿衣表征的需求越来越大.
- 需要标准化,客观的测量方法来测量水服的质量.
- 专注于像新烯这样的湿衣材料的机械和热性能.
研究的目的:
- 描述和比较两种不同的测量方法用于烯湿衣热电阻.
- 为了验证一种新的,简化的实验设置用于热特性.
- 评估一种瞬态方法与静态方法的准确性和可行性.
主要方法:
- 开发了两种方法:遵循法规的固定方法和一种新的过渡方法.
- 这两种方法都使用了圆柱形的湿衣样本,围绕着冷水中加热的幻影.
- 测量热平稳状态 (静态) 和热时间常数 (瞬态) 来确定热电阻.
主要成果:
- 无论是静止方法还是过渡方法,都成功评估了湿衣的热电阻.
- 静止方法提供了更高的准确性,但需要复杂的设置和更多的能量.
- 过渡方法更容易实施,并产生了相似的结果 (0.104{9) m2·K/W与0.095{9) K·m2/W).
结论:
- 拟议的短暂方法是一种有效和实用的替代方法,用于描述湿衣隔热的特点.
- 这种新的方法简化了实验设置和测量.
- 结果与文献价值一致,证实了新方法的可靠性.
更多相关视频
相关概念视频
Resistivity
3.4K
When a voltage is applied to a conductor, an electrical field is generated, and charges in the conductor feel the force due to the electrical field. The current density that results depends on the electrical field and the properties of the material. In some materials, including metals at a given temperature, the current density is approximately proportional to the electrical field. In these cases, the current density can be modeled as:
3.4K
Resistance and Conductance
75
A conductor's DC resistance at a given temperature is influenced by its resistivity, length, and cross-sectional area. Resistivity is an inherent property of the conductor material, with annealed copper serving as the international standard for measurement. For instance, the resistivity of hard-drawn aluminum at 20 degrees Celsius is 61% of the standard conductivity of annealed copper.
Various factors impact the resistance of a conductor. Spiraling in stranded conductors increases their...
Various factors impact the resistance of a conductor. Spiraling in stranded conductors increases their...
75
Resistance
4.4K
When a current moves through any conductor, the conductor causes some level of difficulty for the current to flow. The measure of that difficulty is known as the resistance of the material and is represented by R. Every material has its own resistance. In the case of conductors, heat is emitted whenever a current passes through them. Resistance depends on the resistivity of the material. Resistivity is a characteristic of the material used to fabricate electrical components, whereas the...
4.4K
Electrical Conductivity
1.1K
In perfect conductors, the electric field inside is always zero due to the abundance of free electrons, which nullify any field by flowing. As a result, any residual charge resides on the surface.
In a practical conductor, an applied electric field may be sustained, causing a flow of electrons, which produce a current. The differential form of the current, the current density, is related to the electric field.
More generally, it is related to the force per unit charge, which involves the...
In a practical conductor, an applied electric field may be sustained, causing a flow of electrons, which produce a current. The differential form of the current, the current density, is related to the electric field.
More generally, it is related to the force per unit charge, which involves the...
1.1K
Equipments Used to Measure Body Temperature
983
Body temperature can be assessed using various devices and measured in Celsius or Fahrenheit.
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
983
Thermal expansion and Thermal stress: Problem Solving
1.1K
San Francisco's Golden Gate Bridge is exposed to temperatures ranging from -15 °C to 40 °C. At its coldest, the main span of the bridge is 1275 m long. Assuming that the bridge is made entirely of steel, what is the change in its length between these temperatures?
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in...
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in...
1.1K