空气中的金属纳米颗粒通过亚化物爆炸释放:确定和潜在的公众暴露
Tianyu Cen1,2, Zheyu Zhang1, Laura Torrent1,3
1Paul Scherrer Institute, PSI Center for Energy and Environmental Sciences, PSI, 5232, Villigen, Switzerland.
Scientific reports
|July 27, 2024
概括
引爆金属化物会释放纳米粒子. 这项研究描述了来自银和铜化物的空气中金属纳米粒子,有助于对安全气囊和射击场的风险评估.
科学领域:
- 材料科学 材料科学 材料科学
- 纳米技术纳米技术
- 环境健康 环境健康
背景情况:
- 金属亚化物是用于安全气囊和弹药的高能材料.
- 人们对吸入来自阿齐德爆炸的有害金属颗粒存在担忧.
- 关于空气中的粒子特性和表征方法的知识缺口仍然存在.
研究的目的:
- 为了研究来自阿齐德爆炸的空气金属颗粒.
- 为了描述颗粒大小分布和化学成分.
- 开发用于纳米粒子检测的分析方法.
主要方法:
- 在手套箱中引爆毫克数量的银化物和铜化物.
- 使用整体分析设置对空气中的颗粒进行实时分析.
- 测量颗粒大小分布和化学成分.
主要成果:
- 在2-500nm的尺寸范围内检测到球形金属纳米粒子.
- 成功描述了来自阿齐德爆炸的空气中的颗粒.
- 开发用于纳米粒子识别的分析工具.
结论:
- 空气中的金属纳米粒子是由银和铜化物爆炸产生的.
- 开发的分析方法可以在汽车内部和射击场等环境中识别纳米粒子.
- 这些发现有助于评估与金属化物使用相关的公共卫生风险.
相关概念视频
Atomic Absorption Spectroscopy: Atomization Methods
393
Atomic Absorption Spectroscopy (AAS) atomizes samples through flame atomization or electrothermal atomization. Flame atomization typically involves a nebulizer and spray chamber assembly to combine the sample with a fuel–oxidant mixture, creating a fine aerosol mist that enters a burner. Typically, the fuel and oxidant are combined in an approximately stoichiometric ratio. However, for atoms that are easily oxidized, a fuel-rich mixture may be more advantageous. Only about 5% of the...
393
Atomic Emission Spectroscopy: Interference
178
In atomic emission spectroscopy (AES), high-temperature atomizers excite a broad range of elements and molecules that generate complex emissions from sources such as oxides, hydroxides, and flame combustion products in the flame or plasma. Several strategies can be employed to minimize spectral interferences caused by overlapping emission lines or bands. These include increasing instrument resolution, choosing alternative emission lines, optimally placing the detector in low-background regions,...
178
Atomic Emission Spectroscopy: Overview
1.8K
Atomic emission spectroscopy (AES) is an analytical technique used to determine the elemental composition of a sample by analyzing the light emitted from excited atoms. In AES, atoms in a sample are excited to higher energy levels by thermal energy from high-temperature sources, such as plasma, arcs, or sparks. When these excited atoms return to lower energy states, they emit light at specific wavelengths characteristic of each element. The resulting atomic emission spectrum, which consists of...
1.8K
Atomic Emission Spectroscopy: Lab
152
AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...
152