离子间隙的诊断准确性,以确定有毒的度:一个单中心的回顾性观察研究
Hiroyuki Honda1, Kazuki Deuchi2, Makusu Fukasawa2
1Department of Critical Care Medicine, Niigata University Medical and Dental Hospital, Niigata City, Japan.
Clinical toxicology (Philadelphia, Pa.)
|July 29, 2024
概括
的毒性可以通过减少的离子间隙来表明. 纠正的离子间隙计算,考虑到专蛋白和乳酸盐,可能有助于识别无需直接测量的有毒水平.
科学领域:
- 临床化学 临床化学
- 毒理学 毒理学 毒理学
- 内部医学 内部医学
背景情况:
- 疗法具有狭窄的治疗指数,增加了毒性风险.
- 减少的离子间隙曾经与毒性有关,但这种关系需要澄清.
- 血液水平的直接测量是标准的,但可能耗时.
研究的目的:
- 评估各种离子间隙计算方法在检测有毒度方面的有用性.
- 为了确定校正的离子间隙值是否可以作为毒性的指标.
- 评估不同离子间隙方法的诊断性能,以确定升高的水平.
主要方法:
- 血液样本的回顾性分析与度测量.
- 使用常规,白蛋白校正和白蛋白和乳酸校正方法计算阳离子间隙.
- 较低度 (<1.5 mmol/L) 和有毒度 (≥1.5 mmol/L) 的样本之间的离子间隙值的比较.
- 统计分析包括相关性,后勤回归和接收器运行特征 (ROC) 曲线.
主要成果:
- 41.7%的样本具有有毒度 (≥1.5 mmol/L).
- 含量较高的样本显示阴离子间隙值明显较低.
- 蛋白和乳酸校正的离子间隙方法显示出最高的诊断准确度 (曲线下的面积为0.86).
结论:
- 离子间隙,特别是当对专蛋白和乳酸盐进行校正时,可以成为潜在毒性的有价值指标.
- 纠正的离子间隙测量可能有助于早期检测升高的水平,可能减少立即直接度测试的需要.
- 阳离子间隙值可能有助于排除毒性,正如负概率为0.1.1所建议的那样.
相关概念视频
Electrogravimetric Analysis: Overview
213
Electrogravimetric analysis measures the weight of an analyte deposited electrolytically onto a suitable working electrode. This method involves applying a potential to a pre-weighed electrode submerged in a solution, which results in the desired substance being deposited through reduction at the cathode or oxidation at the anode. The electrode's weight is recorded after deposition, and the difference in weight gives the analyte's weight in the solution.
To test the completeness of the...
To test the completeness of the...
213
Extraction: Advanced Methods
436
Metal ions can be separated from one another by complexation with organic ligands–the chelating agent– to form uncharged chelates. Here, the chelating agent must contain hydrophobic groups and behave as a weak acid, losing a proton to bind with the metal. Since most organic ligands used in this process are insoluble or undergo oxidation in the aqueous phase, the chelating agent is initially added to the organic phase and extracted into the aqueous phase. The metal-ligand complex is...
436