评估便携式X射线光器对金属化物检测和土壤污染状况的可靠性
Zain Alabdain Alqattan1, Janick F Artiola1, Dan Walls1,2
1Department of Environmental Science, College of Agriculture, Life and Environmental Sciences, University of Arizona, Tucson, AZ, USA.
Environmental monitoring and assessment
|July 29, 2024
概括
便携式X射线光光谱 (pXRF) 是用于监测边缘化社区的土壤污染物的诱导合等离子体质谱 (ICP-MS) 的可靠和经济有效的替代方案. 这种方法准确地测量了关键元素,有助于环境公共卫生工作.
科学领域:
- 环境科学 环境科学
- 分析化学 分析化学
- 公共卫生 公共卫生
背景情况:
- 边缘化社区在土壤监测和知识转移方面面临障碍.
- 准确的土壤污染物分析对环境公共卫生至关重要.
- 传统的方法,如ICP-MS是有效的,但昂贵和耗时.
研究的目的:
- 为了比较便携式X射线光光谱 (pXRF) 与感应合等离子体质谱法 (ICP-MS) 的有效性,用于土壤污染物分析.
- 评估pXRF在具有不同土壤准备实践的边缘化社区的可靠性.
- 确定pXRF是否是一种可行的,具有成本效益的环境监测替代方案.
主要方法:
- 从住宅 (美国亚利桑那州) 和公共场所 (美国纽约特洛伊州) 采集了地表土壤样本.
- 使用pXRF和ICP-MS分析样本,同时考虑不同的土壤准备方法.
- 使用统计分析 (t-test,ANOVA,Bland-Altman图片) 和计算的污染指数 (PLI,EF,Igeo).
主要成果:
- 对于几个元素 (As,Ba,Ca,Cu,Mn,Pb,Zn),pXRF与ICP-MS没有显著差异.
- 污染负荷指数 (PLI) >1表示这两个州的土壤污染.
- 对于大多数元素,pXRF表现出与ICP-MS类似的污染评估,对于关键污染物证明可靠.
结论:
- pXRF是一种可靠且具有成本效益的工具,用于选土壤样本的常见环境污染物.
- 这种方法可以改善贫困社区的土壤监测,支持环境公共卫生.
- pXRF为评估土壤污染提供了一种实用的ICP-MS替代方案.
相关概念视频
Atomic Emission Spectroscopy: Overview
1.8K
Atomic emission spectroscopy (AES) is an analytical technique used to determine the elemental composition of a sample by analyzing the light emitted from excited atoms. In AES, atoms in a sample are excited to higher energy levels by thermal energy from high-temperature sources, such as plasma, arcs, or sparks. When these excited atoms return to lower energy states, they emit light at specific wavelengths characteristic of each element. The resulting atomic emission spectrum, which consists of...
1.8K
Atomic Absorption Spectroscopy: Lab
322
For AAS measurements, samples must be introduced as clear solutions, often requiring extensive preliminary treatment to dissolve materials like soils, animal tissues, and minerals. Common methods for sample preparation include treatment with hot mineral acids, wet ashing, combustion in closed containers, high-temperature ashing, or fusion with reagents.
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
322
Atomic Emission Spectroscopy: Lab
152
AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...
152
Photoluminescence: Applications
385
Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...
385