基于ACGAN和CGWO-LSSVM的变压器故障诊断方法的研究
Shan Guan1, Tong-Yu Wu2, Hai-Qi Yang1
1School of Mechanic Engineering, Northeast Electric Power University, Jilin, 132012, China.
Scientific reports
|July 31, 2024
概括
本研究介绍了一种使用ACGAN和CGWO-LSSVM的先进变压器故障诊断方法. 该方法提高了诊断的准确性,特别是在不平衡的数据集,达到97.66%的准确性.
科学领域:
- 电气工程 电气工程
- 人工智能的人工智能
背景情况:
- 变压器故障诊断对于电力系统可靠性至关重要.
- 小而不均分布的故障样本导致误判和精度低.
- 现有的方法与不平衡的数据集作斗争.
研究的目的:
- 为不平衡的数据集开发一个强大的变压器故障诊断方法.
- 提高诊断准确度,降低误判率.
- 为了解决传统故障诊断技术的局限性.
主要方法:
- 使用辅助分类器生成对抗网络 (ACGAN) 来增强不平衡样本的数据.
- 采用非编码比率和内核主要组件分析 (KPCA) 用于溶解气体特征结构和特征融合.
- 使用立方灰狼优化 (CGWO) 算法优化最小方位支向量机 (LSSVM) 参数.
主要成果:
- 实现了97.66%的诊断准确率,低误报率.
- 与IGOA-LSSVM,ICHOA-LSSVM和PSO-LSSVM方法相比,已经证明了更高的性能.
- 有效地解决了由于样本分布小而不均而导致的错误判断和低准确性问题.
结论:
- 拟议的ACGAN和CGWO-LSSVM方法为变压器故障诊断提供了一个优越的解决方案.
- 这种技术非常适合在不平衡变压器数据集上的多分类故障诊断.
- 该方法显著提高了电力系统的诊断可靠性和准确性.
相关概念视频
Power System Three-Phase Short Circuits
79
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
79
Energy Losses in Transformers
852
In an ideal transformer, it is assumed that there are no energy losses, and, hence, all the power at the primary winding is transferred to the secondary winding. However, in reality, the transformers always have some energy losses, and, hence, the output power obtained at the secondary winding is less than the input power at the primary winding due to energy losses.
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
852
Fault Types
83
When analyzing a single line-to-ground fault from phase A to ground at a three-phase bus, it is important to consider the fault impedance. This impedance is zero for a bolted fault, equal to the arc impedance for an arcing fault, and represents the total fault impedance for a transmission-line insulator flashover. To derive sequence and phase currents, fault conditions are translated from the phase domain to the sequence domain.
For line-to-line faults occurring between phases B and C, the...
For line-to-line faults occurring between phases B and C, the...
83
Three-Phase Short Circuit—Unloaded Synchronous Machine
133
Conducting a three-phase short circuit test on an unloaded synchronous machine helps understand its impact on the system. The AC fault current's oscillogram, with the DC offset removed, reveals that the waveform amplitude decreases from an initially high value to a steady-state level for one phase of the machine.
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
133
Equivalent Circuits for Practical Transformers
406
The practical equivalent circuits of single-phase two-winding transformers exhibit significant deviations from their idealized versions due to the inherent properties of winding resistance and finite core permeability. These properties result in real and reactive power losses, affecting the transformer's performance. Understanding these deviations is crucial for designing more efficient transformers.
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
406
Transformers with Off-Nominal Turns Ratios
149
In scenarios involving parallel transformers with disparate ratings, developing per-unit models requires accommodating off-nominal turns ratios. This situation arises when the selected base voltages are not proportional to the transformer’s voltage ratings. Consider a transformer where the rated voltages are related by the term a. If the chosen voltage bases satisfy a relationship involving term b, term c is defined as the ratio of these bases. This ratio is then substituted into the...
149