用达西方程改进现场掉头试验和确定液压导电率
1Korea Institute of Geoscience and Mineral Resources, Daejeon, 34132, South Korea. lbj@kigam.re.kr.
Scientific reports
|August 2, 2024
概括
一个新的周长设计准确地测量了垂直液压导电性 (K) 在现场下降头试验中. 这种创新工具简化了流量和梯度计算,与达尔西对齐.
科学领域:
- 地质技术工程 地质技术工程
- 环境科学 环境科学
- 水文地质学 水文地质学
背景情况:
- 准确地确定垂直液压导电性 (K) 对于了解地下水流和污染物运输至关重要.
- 传统的落头部实地测试可能是复杂和耗时的.
研究的目的:
- 为实地降落头试验引入一种新的周边设计.
- 用达西方程来验证设计能够准确确定垂直液压导电性 (K) 的能力.
主要方法:
- 这种新型的透米仪具有一个开放端的支架管,具有两个端口,用于同时测量液压头.
- 流量 (q) 和液压梯度 (i) 是直接估计从头部差异和水位变化.
- 达西方程用于计算K,结果与Hvorslev方程方法相比较.
主要成果:
- 实验室和实地测试显示,q和i (R2 > 0.999) 之间存在强烈的线性关系,证实了达西方程的适用性.
- 通过新设计获得的K值与Hvorslev方法获得的值相匹配.
- 测试后的连续头部监控使得透率时间序列计算成为可能.
结论:
- 新的周边设计是可靠和高效的工具,用于垂直液压导电的场测定.
- 设计方便先进的分析,包括漏率时间序列,增强水文研究.
- 这种方法为现场地下表征提供了可靠的方法.
相关概念视频
Flow Table Test
140
The flow table test is an established method used to assess the workability of concrete, particularly useful for evaluating highly flowable concrete mixes. This test employs an apparatus that consists of a wooden board topped with a steel plate, collectively weighing 35 pounds. The board is connected to a base via a hinge and measures 27.6 inches on each side.
Concrete is placed within a truncated cone mold that is 8 inches high with an 8-inch base diameter and a 5-inch top diameter. The...
Concrete is placed within a truncated cone mold that is 8 inches high with an 8-inch base diameter and a 5-inch top diameter. The...
140
Non-destructive Tests for Concrete Strength
113
The rebound hammer test, also known as the Schmidt hammer test, is a non-destructive technique for evaluating the hardness of concrete and, indirectly, the strength of concrete. It operates on the principle that the rebound of a spring-driven mass from a concrete surface correlates to the surface's hardness. The device comprises a mass within a tubular housing, a spring mechanism, and a plunger that strikes the concrete. Upon release, the energy imparted to the mass by the spring causes it...
113
Uniform Depth Channel Flow
64
Uniform depth channel flow keeps fluid depth consistent along channels such as irrigation canals. In natural channels, such as rivers, approximate uniform flow is often assumed. This condition occurs when the channel’s bottom slope matches the energy slope, balancing potential energy lost from gravity with head loss due to shear stress. This balance prevents depth changes along the channel length, resulting in a steady, uniform flow.Uniform flow in open channels with a constant cross-section...
64
Uniform Depth Channel Flow: Problem Solving
60
To calculate the flow rate for a trapezoidal channel, first, identify the bottom width, side slope, and flow depth of the channel. The cross-sectional area (A) corresponding to the depth of flow (y), channel bottom width (B), and side slope (θ) is determined by:Next, calculate the wetted perimeter, which includes the bottom width and the sloped side lengths in contact with the water. Using the values of the cross-sectional area and the wetted perimeter, determine the hydraulic radius by...
60
Major Losses in Pipes
1.1K
When a fluid flows through a pipe, it experiences energy losses due to frictional resistance along the pipe walls, known as major losses. These energy losses result in a pressure drop, which varies based on the flow conditions — whether laminar or turbulent — and the specific physical properties of the fluid and pipe.
Fluid flow can be classified as laminar or turbulent, primarily based on the Reynolds number. This dimensionless number reflects the relative influence of inertial to...
Fluid flow can be classified as laminar or turbulent, primarily based on the Reynolds number. This dimensionless number reflects the relative influence of inertial to...
1.1K
Dimensional Analysis
313
Dimensional analysis is a valuable technique in fluid mechanics for simplifying complex problems by reducing them into dimensionless groups. These groups capture the essential relationships between the variables involved, allowing researchers and engineers to analyze fluid flow without dealing with each variable individually. This approach reduces the number of independent variables, allowing for easier analysis and better understanding of physical phenomena.
In fluid mechanics, dimensional...
In fluid mechanics, dimensional...
313