对血阿尔多斯特的校正提高了重复定时尿样的准确性,用于估计饮食摄入量
Anne Myrthe C van Vliet1,2, Liffert Vogt3,4, Bigina N R Ginos3,4
1Nephrology, Amsterdam UMC Location University of Amsterdam, Amsterdam, The Netherlands, a.m.vanvliet@amsterdamumc.nl.
Kidney & blood pressure research
|August 4, 2024
概括
经过多次定时尿液采集,并对血中阿尔多斯特进行校正,可以比单个24小时尿液样本更准确地评估每日摄入量. 这种提高的准确性对于长期的平衡研究至关重要.
科学领域:
- 内分泌学 在内分泌学.
- 营养科学 营养科学
- 临床研究 临床研究
背景情况:
- 平衡受阿尔多和皮质醇的环平律的影响,影响组织的储存和释放.
- 由于这些动态过程,一次24小时尿液采集可能无法可靠地估计个人摄入量.
研究的目的:
- 评估重复定时尿液采集的准确性,以估计每日摄入量.
- 为了确定用血中阿尔多素测量对这些采集进行校正是否能提高准确性.
主要方法:
- 一项对16名健康男性进行的代谢病房研究后期分析,这些男性接受固定的饮食 (50或200毫摩尔/天).
- 每天在四个时间间隔收集尿液 (7:00-13:00, 13:00-19:00, 19:00-23:00, 23:00-07:00小时).
- 每天在三个时间点测量血阿尔多素;在5-7天使用各种公式估计的摄入量.
主要成果:
- 与一次24小时尿液采集相比,多次定时尿液采集,经血阿尔多素校正,在估计摄入量方面显示出明显更高的准确性.
- 在较高的摄入量 (200 mmol/day) 时,定时采集显示了跨间隔的改进,尽管可变,精度.
- 在较低的摄入量 (50 mmol/day) 时,重复定时采集的精度低于单次24小时采集,但阿尔多素校正提高了精度.
结论:
- 经过多次定时尿液采集,当对血中阿尔多素进行校正时,可在受控环境中更准确地估计每日摄入量.
- 这种方法比传统的24小时一次性尿液采集提供了潜在的改善,用于评估平衡.
相关概念视频
Errors occurring during blood pressure monitoring
661
Blood pressure monitoring is a crucial clinical procedure in diagnosing and managing various cardiovascular conditions. Despite its significance, the accuracy of blood pressure measurements can be compromised by multiple factors, potentially leading to either falsely high or low readings. These inaccuracies are critical as they can significantly impact patient care. So, it is vital to understand these challenges deeply and adopt strategic approaches to minimize errors.
Several factors...
Several factors...
661
Regulation of Sodium and Potassium
466
The regulation of sodium and potassium ion concentrations in the human body is a complex process governed primarily by hormones such as aldosterone, antidiuretic hormone (ADH), and atrial natriuretic peptide (ANP).
Sodium Regulation
Sodium ions make up approximately 90% of extracellular cations, with a normal blood plasma concentration of 136–148 mEq/L. A decrease in blood volume and pressure triggers the release of renin from granular cells in the juxtaglomerular complex (JGC), primarily...
Sodium Regulation
Sodium ions make up approximately 90% of extracellular cations, with a normal blood plasma concentration of 136–148 mEq/L. A decrease in blood volume and pressure triggers the release of renin from granular cells in the juxtaglomerular complex (JGC), primarily...
466
Renal Tubule and Collecting Duct
880
The renal tubule is divided into three parts: the proximal convoluted tubule (PCT), the Loop of Henle (LOH), and the distal convoluted tubule (DCT).
Proximal Convoluted Tubule (PCT):
The PCT is the initial segment of the renal tubule, extending from the Bowman's capsule that encloses the glomerulus. Its convoluted structure and microvilli-lined cells increase the surface area for reabsorption. The PCT reabsorbs glucose, amino acids, sodium, and water from the filtrate, ensuring essential...
Proximal Convoluted Tubule (PCT):
The PCT is the initial segment of the renal tubule, extending from the Bowman's capsule that encloses the glomerulus. Its convoluted structure and microvilli-lined cells increase the surface area for reabsorption. The PCT reabsorbs glucose, amino acids, sodium, and water from the filtrate, ensuring essential...
880
Antihypertensive Drugs: Potassium-Sparing Diuretics
488
Liddle syndrome is a genetically inherited form of hypertension characterized by the overactivity of epithelial sodium channels in the nephron, the functional unit of the kidney. This heightened activity leads to increased sodium reabsorption and excessive excretion of potassium. To counteract this, potassium-sparing diuretics such as amiloride are used. They function by blocking these sodium channels, thereby reducing the influx of sodium into the epithelial cells and minimizing the loss of...
488
Assessment of blood pressure in brachial artery(two-step method)
673
Measuring blood pressure is a fundamental skill in healthcare that aids in diagnosing and monitoring hypertension and other cardiovascular conditions. An aneroid sphygmomanometer, commonly used in clinical settings, offers a manual and precise method for blood pressure measurement. The technique for using this instrument involves specific steps that must be carefully executed to ensure accuracy. The following detailed description outlines a two-step technique for assessing blood pressure using...
673


