拆除非水泥组件:希望最好,准备最坏的技术技巧和技巧
C Michael Goplen1,2, Jacob Munro3
1Division of Orthopedic Surgery, Department of Surgery, University of Alberta, Edmonton, Alberta, Canada.
Annals of joint
|August 8, 2024
概括
仔细的手术规划和正确的工具是移除具有挑战性的,固定良好的非水泥植入物的关键. 这种方法最大限度地减少了骨损失,并确保了后续重建的更好的结果.
科学领域:
- 整形外科手术 整形外科手术
- 生物医学工程 生物医学工程
背景情况:
- 移除固定良好的非水泥骨科植入物带来了重大的外科手术挑战.
- 摘除不当可能会导致大量的骨损失,并对修复手术结果产生负面影响.
研究的目的:
- 概述有效的策略和技术,以去除具有挑战性的非水泥化的股骨茎和骨.
- 强调术前规划和专业仪器在成功的植入物提取中发挥的关键作用.
主要方法:
- 对手术技术的审查,用于内和内移除未加的茎,包括扩展的三叉口骨切除术.
- 描述有效地提取非水泥化乙骨的方法.
- 包括案例示例,说明困难的场景,如领,破碎或完全覆盖的茎.
主要成果:
- 周到的手术规划,适当的仪器和适当的技术使大多数非水泥植入物能够快速移除.
- 对以前的记录进行手术前评估对于预测诸如陶轴承或acetabular螺丝等挑战至关重要.
- 成功切除会最大限度地减少骨损失,并促进后续的重建手术.
结论:
- 精心的手术前规划和专用工具的使用对于克服移除固定良好的非水泥植入物的困难至关重要.
- 有效的技术可以显著减少并发症,保持骨库存,并改善患者在修复关节整形术的结果.
更多相关视频
08:42The DREAM Implant: A Lightweight, Modular, and Cost-Effective Implant System for Chronic Electrophysiology in Head-Fixed and Freely Behaving Mice
Published on: July 26, 2024
1.0K
09:51The Transition to an Anterior-Based Muscle Sparing Approach Improves Early Postoperative Function but is Associated with a Learning Curve
Published on: September 7, 2022
2.6K
相关概念视频
Brick Cutting Techniques
135
Brick-cutting techniques involve various tools and methods to shape bricks for construction. A mason's hammer with a chisel-pointed end is used for basic shaping through sharp, precise strikes. For more complex shapes requiring higher precision, a power saw with a water-cooled diamond blade is used.
Cut bricks are categorized by size. Bricks cut to half their original length are called half-bats, while those cut to three-fourths their length are known as three-fourth bats.
Special types of...
Cut bricks are categorized by size. Bricks cut to half their original length are called half-bats, while those cut to three-fourths their length are known as three-fourth bats.
Special types of...
135
Cavity Drainage and Flashings in Masonry walls
76
Typically, a cavity wall consists of two wythes separated by a gap of at least 2 inches, which may contain insulation while still maintaining a minimum clear space of 1 inch to facilitate adequate drainage. Advanced methods like the insertion of a continuous drainage mat can further reduce this space while ensuring effective moisture expulsion.
Weep holes, strategically placed at the base of the cavity, are critical for draining accumulated water. These openings are created by leaving head...
Weep holes, strategically placed at the base of the cavity, are critical for draining accumulated water. These openings are created by leaving head...
76
Placing Concrete
92
The concrete is placed as close as possible to its final position to avoid segregation. The placed concrete is then fully compacted to expel the entrapped air, and the next layer of concrete is laid while the underlying layer is still in the plastic state. The rate at which concrete is placed and compacted is kept equal.
While placing concrete, care is taken to ensure that the concrete is laid in uniform layers, and hand shoveling and moving concrete using poker vibrators is avoided. Also,...
While placing concrete, care is taken to ensure that the concrete is laid in uniform layers, and hand shoveling and moving concrete using poker vibrators is avoided. Also,...
92
Mortar Joint Deterioration in Masonry
112
Mortar joint deterioration is a significant concern in masonry structures, with water accumulation in the joints leading to damage from freeze-thaw cycles. The repeated expansion of water during freezing and its melting during thawing develop and propagate cracks in the masonry joints. Eventually, this leads to the spalling of mortar from the joints, loosening masonry units and weakening the structure. The deteriorated mortar joints are also vulnerable to moisture intrusion into the walls.
The...
The...
112
Types of Cement I
106
Portland cement comes in several types, each with distinct properties and applications based on their chemical composition and hydration characteristics:
Type I (Ordinary Portland Cement) is widely used for general construction where special properties are not required. It has moderate sulfate resistance and heat of hydration.
Type II (Modified Cement) offers moderate resistance to sulfate attack and a lower rate of heat development compared to Type I. It is suitable for structures in...
Type I (Ordinary Portland Cement) is widely used for general construction where special properties are not required. It has moderate sulfate resistance and heat of hydration.
Type II (Modified Cement) offers moderate resistance to sulfate attack and a lower rate of heat development compared to Type I. It is suitable for structures in...
106
Bleeding in Fresh Concrete
111
Bleeding in fresh concrete occurs when water from the mix rises to the surface. This happens because the mix's solid components fail to retain all the water as they settle, leading to separation where water collects at the top. The severity of bleeding can be measured by assessing the total settlement or by noting the decrease in height per unit height of concrete.
Bleeding can cause several issues in the concrete structure. Sometimes, the rising water gets trapped beneath large aggregate...
Bleeding can cause several issues in the concrete structure. Sometimes, the rising water gets trapped beneath large aggregate...
111
