概括
这项研究引入了一种新的方法,利用表面温度和有效持续时间来分解空调的电力消耗. 新的方法和评估指标提高了评估电力使用模式和电网稳定性的准确性.
科学领域:
- 能源系统工程 能源系统工程
- 建筑能源分析分析
- 电网管理 电网管理
背景情况:
- 不断增长的空调电力消耗需要准确的使用细分,以确保电网的稳定性.
- 现有的文献不充分说明表面温度对交流电能使用的影响.
- 缺乏有效的指数阻碍了对交流电力消耗分解精度的评估.
研究的目的:
- 开发一种基于有效持续时间的空调电力消耗分解方法.
- 将表面温度建模集成到交流消耗分解中.
- 提出新的评估指标来评估消费分解的有效性.
主要方法:
- 使用有效持续时间作为分解空调电力消耗的基础.
- 采用表面温度模型作为限制,以确定有效的空调运行时间.
- 构建了一个受约束的凸优化问题,以估计空调功率使用量.
主要成果:
- 拟议的分解方法表明与实际的电力消耗数据更接近.
- 新的评估指数,包括对消极分解消耗的处罚,提高了评估准确性.
- 福建省的实证结果证实了新方法的有效性.
结论:
- 开发的方法提供了更准确的空调电力消耗的分解.
- 提出的评估指标有效地衡量了交流电力消耗数据的质量.
- 这项工作有助于改进电力使用模式评估和电网管理策略.
更多相关视频
10:36Author Spotlight: Optimization of Airflow Velocities in Battery Cooling Systems for Enhanced Thermal Performance and Reduced Energy Consumption
Published on: November 3, 2023
1.5K
04:35Author Spotlight: Simulation and Analysis of the Temperature Rise of Ring Main Unit Equipment
Published on: July 5, 2024
1.8K
相关概念视频
Electrical Energy
1.2K
Using electric appliances for a longer period of time consumes more electrical energy and results in a higher electric bill. The energy produced by the transfer of electrons from one point to another is known as electrical energy. If power is delivered at a constant rate, the electrical energy can be defined as the product of power used by the device for a period of time. The energy unit on electric bills is the kilowatt-hour, where one kilowatt-hour is equivalent to 3.6 × 106 joules.
1.2K
Conservation of AC Power
330
The principle of power preservation is applicable to both ac and dc circuits. This principle, when applied to AC power, asserts that the complex, real, and reactive powers produced by the source are equal to the total complex, real, and reactive powers absorbed by the loads. When two load impedances are connected in parallel to an ac source V, the complex power provided by the source can be calculated using the relation
330
Power in an AC Circuit
2.0K
In a DC circuit, the power consumed is simply the product of the DC voltage times the DC current, given in watts. However, the power consumed for AC circuits with reactive components is calculated differently. Since electrical power is the "rate" at which energy is used in a circuit, all electrical and electronic components and devices have a safe operating range for electrical power.
In a DC circuit, there is no sinusoidal waveform associated with the supply; the voltages and currents...
In a DC circuit, there is no sinusoidal waveform associated with the supply; the voltages and currents...
2.0K
Heating and Cooling Curves
22.8K
When a substance—isolated from its environment—is subjected to heat changes, corresponding changes in temperature and phase of the substance is observed; this is graphically represented by heating and cooling curves.
For instance, the addition of heat raises the temperature of a solid; the amount of heat absorbed depends on the heat capacity of the solid (q = mcsolidΔT). According to thermochemistry, the relation between the amount of heat absorbed or released by a substance, q, and its...
For instance, the addition of heat raises the temperature of a solid; the amount of heat absorbed depends on the heat capacity of the solid (q = mcsolidΔT). According to thermochemistry, the relation between the amount of heat absorbed or released by a substance, q, and its...
22.8K
Refrigerators and Heat Pumps
2.2K
Refrigerators or heat pumps are heat engines operating in a reverse direction. For a refrigerator, the focus is on removing heat from a specific area, whereas, for a heat pump, the focus is on dumping heat into one particular area. A refrigerator (or heat pump) absorbs heat Qc from the cold reservoir at Kelvin temperature Tc and discards heat Qh to the hot reservoir at Kelvin temperature Th, while work W is done on the engine’s working substance.
A household refrigerator removes heat from...
A household refrigerator removes heat from...
2.2K
Average Power
584
In practical electrical applications, the concept of time-varying instantaneous power is not frequently utilized. Instead, focus shifts to the more practical quantity known as average power. Average power is determined by integrating the instantaneous power over a specified time period and subsequently dividing it by that duration.
584