多变量曲线分辨率与端子提取方法在超光谱拉曼成像中的比较
Robert W Schmidt1, Freek Ariese1, Nematollah Omidikia2
1LaserLaB Amsterdam, Department of Physics and Astronomy, Vrije Universiteit Amsterdam, De Boelelaan 1081, 1081 HV Amsterdam, the Netherlands.
概括
多变量曲线分辨率 (MCR) 和端子提取 (EX) 进行了比较,用于高光谱拉曼成像. MCR成功地从复杂样本中提取纯光谱,即使没有纯像素,与EX不同.
科学领域:
- 分析化学 分析化学
- 频谱学是一种光谱学.
- 材料科学 材料科学 材料科学
背景情况:
- 超光谱成像 (HSI) 生成大型数据集,需要进行化学信息提取的前后处理.
- 端子提取 (EX) 和多变量曲线分辨率 (MCR) 是从HSI数据中导出纯光谱特征和丰度图的常用技术.
研究的目的:
- 在拉曼映射中系统地比较纯变量提取的EX和MCR方法.
- 为选择合适的纯变量提取技术提供准则.
主要方法:
- 数字模拟和实验拉曼映射在药品粉末和分层塑料上.
- 将多变量曲线分辨率 (MCR) 和顶点组件分析 (VCA) 作为代表性的EX算法进行比较.
主要成果:
- 当数据集包含每个组件的纯像素时,MCR和EX (VCA) 性能都很好.
- 在数据集中缺少纯像素时,MCR在提取纯成分光谱方面表现出卓越的能力.
结论:
- 纯像素的存在或不存在显著影响EX和MCR算法的性能.
- 在超光谱拉曼成像中,MCR是用于纯光谱签名和丰度地图检索的推方法,特别是在处理缺乏纯像素的复杂样品时.
相关概念视频
Raman Spectroscopy Instrumentation: Overview
320
A conventional Raman spectrophotometer includes a laser source, a sample holding system, a wavelength selector, and a detector.
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
320
Raman Spectroscopy: Overview
349
The underlying principle of Raman spectroscopy is based on the interaction between light and matter, specifically molecules' inelastic scattering of photons. When a monochromatic beam of light, typically from a laser source, interacts with a sample, most scattered light has the same frequency as the incident light. This is known as Rayleigh scattering.
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
349
High-Resolution Mass Spectrometry (HRMS)
1.3K
The resolution of a mass spectrometer depends on the efficiency of separating ions with different ion masses. The mass of an atom is approximated to the sum of the masses of protons and neutrons inside, considering the masses of protons and neutrons as equal. However, the masses of the proton (1.6726 × 10−24 g) and neutron (1.6749 × 10−24 g) are not truly equal. There is a minor error in the expression of atomic masses relative to the simplest atom of hydrogen. For...
1.3K
Chromatographic Resolution
444
In chromatography, a solute moves through a chromatographic column and tends to spread, forming a Gaussian-shaped band. The longer the solute spends in the column, the broader the band becomes. The broadening can lead to overlaps within the column, affecting separation effectiveness.
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
444
NMR Spectrometers: Resolution and Error Correction
680
When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
680