部分放电检测,诊断和定位技术基于用于开关设备的新型过渡性地球电压-超声波集成传感器
Xutao Han1, Haotian Wang1, Yuan Sun1
1National Key Laboratory of Electrical Materials and Insulation, Xi'an Jiaotong University, Xi'an 710049, China.
The Review of scientific instruments
|August 12, 2024
概括
一个新的集成传感器结合了暂时地球电压 (TEV) 和超声波方法来检测电气开关设备中的部分放电 (PD). 这种新型传感器提供了灵敏的检测,精确的定位和中压 (MV) 和气体绝缘开关设备 (GIS) 绝缘故障的准确诊断.
科学领域:
- 电气工程 电气工程
- 电力系统 电力系统
- 材料科学 材料科学 材料科学
背景情况:
- 中压 (MV) 交换机和气体隔热交换机 (GIS) 对电网可靠性至关重要.
- MV开关设备和GIS的绝缘故障可能导致操作故障.
- 部分放电 (PD) 是绝缘体退化的关键指标.
研究的目的:
- 开发和评估一种新型的集成传感器,用于同时测量Transient Earth Voltage (TEV) 和超声波PD.
- 评估传感器在MV开关设备和GIS中检测和定位PD的性能.
主要方法:
- 开发一个集成的TEV-超声波传感器,具有独立的结构部件.
- 在专用平台上对传感器的性能测试.
- 在10kV开关设备和220kV GIS中进行PD测量实验.
主要成果:
- 集成的传感器成功地在同一位置同时测量了TEV和超声波信号.
- 证明了PD的有效和敏感的检测能力.
- 实现了PD事件的精确定位和准确诊断.
结论:
- 新型TEV-超声波集成传感器为MV开关设备和GIS中的PD监控提供了统一的方法.
- 这种综合方法提高了绝缘故障诊断的准确性和效率.
- 该传感器为提高电网组件的运行安全性和可靠性提供了一个有希望的解决方案.
相关概念视频
Three-Phase Short Circuit—Unloaded Synchronous Machine
133
Conducting a three-phase short circuit test on an unloaded synchronous machine helps understand its impact on the system. The AC fault current's oscillogram, with the DC offset removed, reveals that the waveform amplitude decreases from an initially high value to a steady-state level for one phase of the machine.
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
133
Instrument Transformers
80
Instrument transformers, comprising voltage transformers (VTs) and current transformers (CTs), play crucial roles in power substations by providing isolated replicas of current or voltage for measurement and protection purposes. Voltage transformers reduce the primary voltage to levels suitable for relay operation and measurement, while current transformers scale down the primary current. The primary winding of a current transformer often consists of a single turn, achieved by threading the...
80
Insulation Coordination
125
Insulation coordination is the process of matching electric equipment's insulation strength with protective device characteristics to protect the equipment against expected overvoltages. This selection is based on engineering judgment and cost. Equipment can generally withstand short-duration high transient overvoltages, but repeated tests with identical waveforms can yield inconsistent results. As a result, standard impulse voltage waveforms are used for testing, defined by specific times...
125
Reclosers and Fuses
100
Automatic circuit reclosers enhance the protection of distribution circuits by interrupting and auto-reclosing an AC circuit according to a preset sequence. They effectively manage temporary faults on overhead distribution lines, often caused by tree limbs or wildlife, by briefly disrupting service to improve overall reliability. However, contact with reclosers or energized broken conductors on the ground can pose serious hazards.
A comprehensive protection scheme for radial distribution...
A comprehensive protection scheme for radial distribution...
100
Overcurrent Relays
76
Overcurrent relays, crucial for circuit protection, are connected to the secondary current of a current transformer. There are two primary types of overcurrent relays: instantaneous and time-delay.
Instantaneous overcurrent relays activate immediately when the input current exceeds a predetermined value, known as the pickup current, instantly energizing the circuit breaker trip coil. This rapid response is vital for addressing severe faults quickly.
Time-delay overcurrent relays, on the other...
Instantaneous overcurrent relays activate immediately when the input current exceeds a predetermined value, known as the pickup current, instantly energizing the circuit breaker trip coil. This rapid response is vital for addressing severe faults quickly.
Time-delay overcurrent relays, on the other...
76
Line Protection with Impedance Relays
70
Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
Under normal conditions, low load currents keep the measured...
70