对复杂相对于实域线性组合模型的精度和准确性的改进,光谱拟合不一定通过零填充恢复
Leonardo Campos1, Kelley M Swanberg1, Martin Gajdošík1
1Biomedical Engineering, Columbia University, New York, New York, USA.
NMR in biomedicine
|August 13, 2024
概括
在质子磁共振光谱 (H MRS) 中使用复杂的数据可以提高代谢物量化的准确性. 复杂的装配的好处并不总是被零填充所否定,尤其是在体内基线上.
科学领域:
- 磁共振成像技术 磁共振成像技术
- 生物医学光谱学 生物医学光谱学
- 定量分析 定量分析
背景情况:
- 在体内质子磁共振光谱 (H MRS) 产生复杂值的光谱.
- 目前的光谱量化通常使用线性组合建模 (LCM),仅使用真实光谱.
- 使用复杂与真实数据和零填充对LCM安装的影响尚未得到充分证实.
研究的目的:
- 为了比较使用完整复杂数据与真实数据的LCM安装结果.
- 调查零填充对LCM配件在复杂和真实领域的影响.
- 评估量化准确性和精度的改进.
主要方法:
- 线性组合建模 (LCM) 应用于模拟和测量的光谱数据.
- 在复杂和真实领域评估LCM合适错误.
- 使用三种合成数据类型进行测试:洛伦兹单元,没有基线的代谢物光谱和具有体内基线的代谢物光谱.
主要成果:
- 复杂的装配在所有测试数据类型中始终提高了合适度和精度.
- 零填充降低了复杂配合对简单光谱 (单片,没有基线的代谢物光谱) 的好处.
- 复杂的配合效益即使在光谱零填充的情况下也持续存在,包括测量的体内基线.
结论:
- 在复杂的领域中执行LCM可以提高代谢物量化准确度,而不是只有真实匹配.
- 零填充可以提供类似的好处,复杂的配合的光谱与平面基线.
- 复杂域配合的优势并非普遍取代所有体内光谱基线类型的零填充.
更多相关视频
06:50O-cresol Concentration Online Measurement Based On Near Infrared Spectroscopy Via Partial Least Square Regression
Published on: November 8, 2019
6.6K
08:12Author Spotlight: Exploring Light-Driven Chemical Reactions and Energy-Harnessing Devices in Photochemical Research
Published on: February 16, 2024
8.8K
相关概念视频
Linear Approximation in Frequency Domain
88
Linear systems are characterized by two main properties: superposition and homogeneity. Superposition allows the response to multiple inputs to be the sum of the responses to each individual input. Homogeneity ensures that scaling an input by a scalar results in the response being scaled by the same scalar.
In contrast, nonlinear systems do not inherently possess these properties. However, for small deviations around an operating point, a nonlinear system can often be approximated as linear....
In contrast, nonlinear systems do not inherently possess these properties. However, for small deviations around an operating point, a nonlinear system can often be approximated as linear....
88
Linear Approximation in Time Domain
75
Nonlinear systems often require sophisticated approaches for accurate modeling and analysis, with state-space representation being particularly effective. This method is especially useful for systems where variables and parameters vary with time or operating conditions, such as in a simple pendulum or a translational mechanical system with nonlinear springs.
For a simple pendulum with a mass evenly distributed along its length and the center of mass located at half the pendulum's length,...
For a simple pendulum with a mass evenly distributed along its length and the center of mass located at half the pendulum's length,...
75
Accuracy, limits, and approximation
445
Accuracy, limits, and approximations are common in many fields, especially in engineering calculations. These concepts are imperative for ensuring that a given value is as close as possible to its true value.
Accuracy is defined as the closeness of the measured value to the true or actual value. In engineering mechanics, repeated measurements are taken during theoretical or experimental analyses to ensure that the result is precise and accurate.
The accuracy of any solution is based on the...
Accuracy is defined as the closeness of the measured value to the true or actual value. In engineering mechanics, repeated measurements are taken during theoretical or experimental analyses to ensure that the result is precise and accurate.
The accuracy of any solution is based on the...
445
Aliasing
124
Accurate signal sampling and reconstruction are crucial in various signal-processing applications. A time-domain signal's spectrum can be revealed using its Fourier transform. When this signal is sampled at a specific frequency, it results in multiple scaled replicas of the original spectrum in the frequency domain. The spacing of these replicas is determined by the sampling frequency.
If the sampling frequency is below the Nyquist rate, these replicas overlap, preventing the original...
If the sampling frequency is below the Nyquist rate, these replicas overlap, preventing the original...
124
Calibration Curves: Linear Least Squares
1.3K
A calibration curve is a plot of the instrument's response against a series of known concentrations of a substance. This curve is used to set the instrument response levels, using the substance and its concentrations as standards. Alternatively, or additionally, an equation is fitted to the calibration curve plot and subsequently used to calculate the unknown concentrations of other samples reliably.
For data that follow a straight line, the standard method for fitting is the linear...
For data that follow a straight line, the standard method for fitting is the linear...
1.3K
NMR Spectrometers: Resolution and Error Correction
679
When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
679
