电力行业低碳转型效率的空间特征和动态差异
Chaoyong Qin1,2, Yizheng Liang1,2, Yun Cao3,4
1School of Business, Guangxi University, Nanning, 530004, China.
Scientific reports
|August 14, 2024
概括
中国的电力行业表现出提高低碳转型效率,这是技术进步所推动的. 西部地区处于领先地位,而电力价格对效率有积极的影响,与能源结构和法规不同.
科学领域:
- 能源经济学 能源经济学
- 环境科学 环境科学
- 可持续发展 可持续发展 可持续发展
背景情况:
- 全球减少碳排放的迫切需要在电力行业实现低碳转型.
- 可持续发展目标与能源部门的脱碳紧密相关.
研究的目的:
- 评估中国电力行业的低碳转型效率.
- 分析这种过渡的影响因素和时空动态.
- 为优化绿色发展战略提供见解.
主要方法:
- 基于超级epsilon的测量 (超级EBM) 模型用于效率评估.
- 用于生产率分析的马尔姆奎斯特指数.
- 用于因素分析的托比特模型.
主要成果:
- 低碳转型效率的整体上升趋势,其中中国西部处于领先地位.
- 技术进步显著提高了总因素生产率.
- 电价与效率正相关;能源结构,环境法规和经济结构显示出负相关性.
结论:
- 在效率方面存在区域差异,中国西部的效率高但波动.
- 区域内差异正在减少,但中国西部呈现多极分布.
- 空间溢出效应和邻近省份的效率影响动态趋势,可能会产生"西效应".
更多相关视频
06:04Experimental Investigation of the Hierarchical Control in DC Microgrids Using a Real-time Simulator
Published on: February 14, 2025
265
06:57Utilizing Electroencephalography Measurements for Comparison of Task-Specific Neural Efficiencies: Spatial Intelligence Tasks
Published on: August 9, 2016
11.4K
相关概念视频
Maximum Power Flow and Line Loadability
104
The maximum power flow for lossy transmission lines is derived using ABCD parameters in phasor form. These parameters create a matrix relationship between the sending-end and receiving-end voltages and currents, allowing the determination of the receiving-end current. This relationship facilitates calculating the complex power delivered to the receiving end, from which real and reactive power components are derived.
104
Energy Line and Hydraulic Gradient Line
967
Based on Bernoulli's equation, the energy line (EL) and hydraulic grade line (HGL) provide graphical representations of energy distribution in a fluid flow system. For steady, incompressible, inviscid flows, Bernoulli's equation is expressed as:
967
Energy Losses in Transformers
844
In an ideal transformer, it is assumed that there are no energy losses, and, hence, all the power at the primary winding is transferred to the secondary winding. However, in reality, the transformers always have some energy losses, and, hence, the output power obtained at the secondary winding is less than the input power at the primary winding due to energy losses.
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
844
Control of Power Flow
255
There are several methods to control power flow in power systems:
255
Fast Decoupled and DC Powerflow
178
The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
178
Power Factor Correction
162
The power transmission to a factory involves the transfer of apparent power, a combination of active and reactive power. The power factor measures how effectively electrical power is converted into useful work output. The ratio of the real power (KW) that does the work to the apparent power (KVA) supplied to the circuit.
162
