授权配电系统运营商:对分布式能源资源预测技术的审查
Nande Fose1, Arvind R Singh1, Senthil Krishnamurthy1
1Department of Electrical , Electronics and Computer Engineering, Cape Peninsula University of Technology, Bellville Campus, South Africa.
Heliyon
|August 19, 2024
概括
分布式能源资源 (DER) 的准确预测对于配电系统运营商 (DSO) 来说至关重要,以优化电网运营和推进可持续发展目标 (SDGs). 本综述分析了当前的DER预测实践及其对清洁能源,基础设施和气候行动的影响.
科学领域:
- 能源系统工程 能源系统工程
- 可持续发展 可持续发展 可持续发展
- 电网管理 电网管理
背景情况:
- 配电系统运营商 (DSO) 面临着由于分布式能源 (DER) 的整合而增加的复杂性.
- 有效地管理DER对于优化电网运营和实现可持续发展目标至关重要.
研究的目的:
- 批判性地审查当前的DER预测实践的DSO.
- 分析DER预测对实现关键可持续发展目标的影响,包括清洁能源,基础设施和气候行动.
主要方法:
- 关于DER预测技术,数据收集,负载和发电预测模型以及集成策略的综合文献综述.
- 探索人工智能和机器学习在DER预测中的作用.
- 分析DER预测与具体SDG目标之间的联系.
主要成果:
- 准确的DER预测对于优化电网运营,管理能源流量和整合可再生能源至关重要.
- DER预测直接支持与负担得起和清洁能源 (SDG 7),可持续基础设施 (SDG 9),气候行动 (SDG 13) 和伙伴关系 (SDG 17) 相关的可持续发展目标.
- 挑战包括数据可用性,预测准确性,不确定性管理和监管障碍.
结论:
- 推进DER预测技术对于DSO来说至关重要,以充分利用DER为可持续的未来.
- 需要进一步研究改进的算法,数据分析和通信机制.
- 有效的DER预测是实现全球可持续发展目标的关键推动因素.
相关概念视频
Distribution Reliability and Automation
107
Distribution reliability in electrical power systems is critical for ensuring an uninterrupted power supply to consumers at minimal cost. According to IEEE Standard Terms, reliability is the probability that a device will function without failure over a specified time period or amount of usage. For electric power distribution, this translates to maintaining continuous power supply and addressing customer concerns over power outages. Several indices, as defined by IEEE Standard 1366-2012, are...
107
Fast Decoupled and DC Powerflow
178
The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
178
Transformers in Distribution System
99
Transformers in distribution systems can be broadly categorized into distribution substation transformers and other distribution transformers. They are crucial for stepping down high transmission voltages to levels suitable for distribution and end-user applications.
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
99
Power System Distribution
229
Power system distribution involves delivering electrical energy from power plants to consumers through a network of transmission and distribution systems. The process begins at power plants, where energy from coal, gas, nuclear, water, and wind is converted into electrical energy. These plants use three-phase generators, typically rated between 50 to 1300 MVA, with terminal voltages ranging from a few kV to 20 kV, depending on the size and age of the units.
The transmission system is designed...
The transmission system is designed...
229
Secondary Distribution
83
Secondary distribution systems provide electrical energy at the utilization voltage levels from distribution transformers to customer meters. Typical secondary voltages in the United States include 120/240 V for residential use, 208Y/120 V for residential and commercial use, and 480Y/277 V for industrial and high-rise commercial use.
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
83
Load-frequency control
140
Load-frequency control (LFC) is vital for maintaining power system stability, ensuring that frequency and power flows remain within acceptable limits during load changes. Turbine-governor control eliminates rotor accelerations and decelerations following load changes. However, a steady-state frequency error persists when the change in the turbine-governor reference setting is zero. In an interconnected power system, each area agrees to export or import a scheduled amount of power through...
140