无变压器的高增益直流-直流转换器设计和分析用于燃料电池车辆
Belqasem Aljafari1, Tareq Kareri1, Sudhakar Babu Thanikanti2
1Electrical Engineering Department, College of Engineering, Najran University, 11001, Najran, Saudi Arabia.
Scientific reports
|August 19, 2024
概括
本研究介绍了一种用于高功率应用的新型时间共享直流-直流转换器. 新设计实现了显著的电压增益,非常适合燃料电池电动汽车和备用电源系统.
科学领域:
- 电气工程 电气工程
- 电力电子 电力电子 电力电子
- 可再生能源系统可再生能源系统
背景情况:
- 高功率转换器对于工业和商业应用至关重要,例如燃料电池电动汽车 (FCEV),能量备份和汽车照明.
- 现有的单功率比率拓在高功率循环运行方面存在局限性,需要额外的组件来增强电压增益.
研究的目的:
- 引入一种新的时间共享技术,用于高增益的非隔离直流-直流转换器.
- 与传统转换器相比,要实现显著更高的输出电压增益.
主要方法:
- 开发一个时间共享的非隔离的直流-直流转换器拓.
- 对转换器性能特征的理论分析.
- 使用MATLAB/Simulink进行模拟和验证.
主要成果:
- 拟议的转换器实现了大约是输入电压的13.33倍的高输出电压增益.
- 通过MATLAB/Simulink模拟验证理论分析.
- 达到97.4%的高转换效率.
结论:
- 时间共享技术有效地提高了非隔离的直流-直流转换器的电压增益.
- 拟议的转换器是适用于需要显著电压提升的高功率应用的可行解决方案.
- 取得的效率证明了开发的转换器的实际应用.
更多相关视频
相关概念视频
Batteries and Fuel Cells
27.2K
A battery is a galvanic cell that is used as a source of electrical power for specific applications. Modern batteries exist in a multitude of forms to accommodate various applications, from tiny button batteries such as those that power wristwatches to the very large batteries used to supply backup energy to municipal power grids. Some batteries are designed for single-use applications and cannot be recharged (primary cells), while others are based on conveniently reversible cell reactions that...
27.2K
Energy Losses in Transformers
844
In an ideal transformer, it is assumed that there are no energy losses, and, hence, all the power at the primary winding is transferred to the secondary winding. However, in reality, the transformers always have some energy losses, and, hence, the output power obtained at the secondary winding is less than the input power at the primary winding due to energy losses.
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
844
Equivalent Circuits for Practical Transformers
404
The practical equivalent circuits of single-phase two-winding transformers exhibit significant deviations from their idealized versions due to the inherent properties of winding resistance and finite core permeability. These properties result in real and reactive power losses, affecting the transformer's performance. Understanding these deviations is crucial for designing more efficient transformers.
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
404
Bridge rectifier
563
The bridge rectifier is essential in electronics for efficiently converting alternating current (AC) to direct current (DC). Comprised of four diodes configured in a bridge layout, this rectifier effectively processes both the positive and negative halves of the AC waveform, making it superior to half-wave and full-wave center-tapped rectifiers in terms of voltage regulation and output stability.
Operationally, the bridge rectifier allows current flow through two of its diodes during each...
Operationally, the bridge rectifier allows current flow through two of its diodes during each...
563
Fast Decoupled and DC Powerflow
178
The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
178
Three-Winding Transformers
216
Three identical single-phase transformers can be configured to form a three-phase transformer connection, which involves high-voltage and low-voltage windings. The high-voltage windings are denoted by capital letters A-B-C, while the low-voltage windings are labeled with lowercase letters a-b-c, representing their respective phases. This notation helps distinguish between the high and low voltage sides of the transformer.
In the per-unit equivalent circuit of a grounded Y-Y three-phase...
In the per-unit equivalent circuit of a grounded Y-Y three-phase...
216