JT-60SA边缘森散射诊断的采集光学
F A D'Isa1, A Fassina1, L Giudicotti1,2
1Consorzio RFX (CNR, ENEA, INFN, University of Padova, Acciaierie Venete SpA), C.so Stati Uniti 4, 35127 Padova, Italy.
The Review of scientific instruments
|August 21, 2024
概括
该JT-60SA项目使用先进的森散射诊断来测量等离子体特性. 这项研究详细介绍了用于边缘等离子体测量的紧,远心光学设计,这对于融合发电厂的开发至关重要.
科学领域:
- 核聚变工程 核聚变工程
- 等离子体物理学 诊断 诊断
背景情况:
- JT-60SA项目旨在推进核聚变发电厂技术,以补充ITER.
- 诊断系统对于JT-60SA的任务至关重要,森散射 (TS) 是关键.
- 边缘等离子体测量对于理解和控制聚变反应至关重要.
研究的目的:
- 介绍JT-60SA的森边缘散射光学组件的光学设计.
- 详细说明设计特征,在有限的空间内实现所需的视野和空间分辨率.
- 描述开发光学产品的性能验证测试.
主要方法:
- 综合的光机械设计,专注于远程中心性和紧性.
- 为边缘TS系统开发采集光学.
- 性能验证包括焦平面识别,热循环和放大测试.
主要成果:
- 为JT-60SA边缘TS系统设计了一个远程中心和紧的光学组件.
- 该设计成功地解决了有限空间的挑战,同时满足了光学要求.
- 最初的测试证实了光学组件的性能.
结论:
- 设计的光学组件能够满足JT-60SA.边缘等离子体测量的要求.
- 这项工作有助于为未来的核聚变发电厂开发可靠的诊断.
- 成功的光机械设计和测试为实际的核聚变能源铺平了道路.
更多相关视频
相关概念视频
Thomson's e/m Experiment
In a beam of charged particles created by a heated cathode, the particles move at different speeds. However, many applications need a beam with uniform particle speeds. An arrangement known as a velocity selector uses electric and magnetic fields to pick particles with a particular speed from the beam.
A particle with charge q, speed v, and mass m enters an area from the top, where the magnetic and electric fields are perpendicular both to the particle's motion and to one another. The magnetic...
A particle with charge q, speed v, and mass m enters an area from the top, where the magnetic and electric fields are perpendicular both to the particle's motion and to one another. The magnetic...
Atomic Absorption Spectroscopy: Instrumentation
An atomic absorption spectrophotometer (AAS) comprises several components: a radiation source, an atomizer, a monochromator, and a detector. The radiation source can be a hollow-cathode lamp (HCL) or an electrodeless-discharge lamp (EDL), both of which provide a narrow emission line of the required wavelength. However, some instruments use continuum sources and high-resolution monochromators to achieve a narrow range of radiation.
The atomizer used in AAS can be either a flame atomizer or an...
The atomizer used in AAS can be either a flame atomizer or an...
Atomic Emission Spectroscopy: Instrumentation
The instrumentation of atomic emission spectrometry (AES) involves various components, including atomization devices that convert samples into gas-phase atoms and ions. There are two main types of atomization devices: continuous and discrete atomizers. Continuous atomizers, like plasmas and flames, introduce samples in a constant stream, while discrete atomizers inject individual samples using syringes or autosamplers. The most common discrete atomizer is the electrothermal atomizer.
Atomic Emission Spectroscopy: Interference
In atomic emission spectroscopy (AES), high-temperature atomizers excite a broad range of elements and molecules that generate complex emissions from sources such as oxides, hydroxides, and flame combustion products in the flame or plasma. Several strategies can be employed to minimize spectral interferences caused by overlapping emission lines or bands. These include increasing instrument resolution, choosing alternative emission lines, optimally placing the detector in low-background regions,...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Atomic Emission Spectroscopy: Lab
AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...