增加冲击线圈阻抗的正常化与全输出同步冲击阻抗的正常化
Takahide Kadosaka1, Masaya Watanabe1,2, Motoki Nakao1
1Department of Cardiovascular Medicine, Hokkaido University Graduate School of Medicine, Sapporo, Japan.
Journal of cardiovascular electrophysiology
|August 22, 2024
概括
在患有心血管植入式电子设备 (CIED) 的患者中,高低压子值 (LVSM) 冲击阻抗 (SI) 测量可能不准确. 完整的输出冲击测试可以帮助评估高压冲击阻抗 (HVSI) 并使LVSM-SI正常化.
科学领域:
- 心血管植入式电子设备 (CIED) 是一种心血管植入式电子设备.
- 电子生理学 电子生理学
- 生物医学工程 生物医学工程
背景情况:
- 阻抗监测对于CIED功能至关重要.
- 低压下值测量 (LVSM) 常用于阻抗评估.
- 冲击阻抗的LVSM (LVSM-SI) 可能由于围导组织变化而变得不准确.
相关概念视频
Design Example: Automobile Ignition System
219
The automobile's ignition system plays a vital role by ensuring the timely ignition of the fuel-air mixture in each cylinder. This ignition is facilitated by a spark plug, which is composed of two electrodes separated by an air gap. A spark forms across this air gap when a substantial voltage is generated between the electrodes, leading to the ignition of the fuel.
One can generate a large voltage using a car battery of 12 volts with the help of inductors. Inductors are known for opposing...
One can generate a large voltage using a car battery of 12 volts with the help of inductors. Inductors are known for opposing...
219
Voltage Doubler Circuit
505
A voltage doubler circuit integrates two main components: a clamping section and a rectifier section. The clamping section consists of a capacitor (C1) and a diode (D1), whereas the rectifier section is equipped with another diode (D2) and capacitor (C2). This circuit produces an output voltage with twice the amplitude of the sinusoidal input voltage.
505
Magnetic Damping
437
Eddy currents can produce significant drag on motion, called magnetic damping. For instance, when a metallic pendulum bob swings between the poles of a strong magnet, significant drag acts on the bob as it enters and leaves the field, quickly damping the motion.
If, however, the bob is a slotted metal plate, the magnet produces a much smaller effect. When a slotted metal plate enters the field, an emf is induced by the change in flux; however, it is less effective because the slots limit the...
If, however, the bob is a slotted metal plate, the magnet produces a much smaller effect. When a slotted metal plate enters the field, an emf is induced by the change in flux; however, it is less effective because the slots limit the...
437
Magnetic Field Due to Two Straight Wires
2.4K
Consider two parallel straight wires carrying a current of 10 A and 20 A in the same direction and separated by a distance of 20 cm. Calculate the magnetic field at a point "P2", midway between the wires. Also, evaluate the magnetic field when the direction of the current is reversed in the second wire.
2.4K
Line Protection with Impedance Relays
69
Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
Under normal conditions, low load currents keep the measured...
69
Insulation Coordination
125
Insulation coordination is the process of matching electric equipment's insulation strength with protective device characteristics to protect the equipment against expected overvoltages. This selection is based on engineering judgment and cost. Equipment can generally withstand short-duration high transient overvoltages, but repeated tests with identical waveforms can yield inconsistent results. As a result, standard impulse voltage waveforms are used for testing, defined by specific times...
125