开发用于高强度漫游磁场环境的快速2.5 MeV中子探测器
A Dal Molin1, F Guiotto2,3, O Putignano1
1Istituto per la Scienza e Tecnologia dei Plasmi, CNR, Milan, Italy.
The Review of scientific instruments
|August 22, 2024
概括
一个使用EJ-276D闪电器和SiPM的新中子探测器对磁场不敏感. 这一发展有助于通过近距离测量来评估小型聚变装置的性能.
科学领域:
- 核聚变技术是核聚变技术的一种.
- 粒子检测系统 粒子检测系统
背景情况:
- 小到中等规模的磁束聚变装置使用燃料.
- 精确的中子测量 (2.45 MeV) 对于验证模型和评估低中子速率 (10^8-10^10 n/s) 环境中的性能至关重要.
- 为了最大限度地利用数据,中子监测器与核聚变装置的接近是必要的,但强烈的漫游磁场构成了挑战.
研究的目的:
- 开发一种新型中子探测器,适合在磁束聚变装置中运行.
- 创建一个能够精确测量中子的探测器系统,尽管存在强磁场.
- 提高低中子速率聚变实验的性能评估能力.
主要方法:
- 使用EJ-276D闪器晶体开发一个中子探测器.
- 将闪电器与光倍增器 (SiPM) 合起来,用于信号检测.
- 为探测器设计和实施定制的读数系统.
- 在探测器系统中整合颗粒区分能力.
主要成果:
- 开发的中子探测器展示了粒子区分能力.
- 探测器系统对磁场不敏感,这是其预期应用的关键要求.
- 该探测器设计用于在聚变装置中近距离放置,从而优化数据采集.
结论:
- 新型中子探测器是一个可行的解决方案,用于评估低中子率的磁束聚变装置的性能.
- 磁场不敏感性和粒子辨别特性解决了聚变诊断中的关键挑战.
- 这种技术进步支持在核聚变研究中更准确的物理模型验证和设备优化.
更多相关视频
10:24Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor
Published on: May 7, 2021
2.3K
11:27Studying Soft-matter and Biological Systems over a Wide Length-scale from Nanometer and Micrometer Sizes at the Small-angle Neutron Diffractometer KWS-2
Published on: December 8, 2016
12.3K
相关概念视频
Mass Analyzers: Common Types
579
The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
579
Atomic Nuclei: Nuclear Relaxation Processes
632
In the absence of an external magnetic field, nuclear spin states are degenerate and randomly oriented. When a magnetic field is applied, the spins begin to precess and orient themselves along (lower energy) or against (higher energy) the direction of the field. At equilibrium, a slight excess population of spins exists in the lower energy state. Because the direction of the magnetic field is fixed as the z-axis, the precessing magnetic moments are randomly oriented around the z-axis.
632
Diamagnetic Shielding of Nuclei: Local Diamagnetic Current
845
An applied magnetic field causes the electrons present in the molecule to circulate, setting up a local diamagnetic current within the molecule. The local diamagnetic current arising from circulating sigma-bonding electrons induces a magnetic field, Blocal that opposes the applied magnetic field, B0. The effective magnetic field experienced by these nuclei is given by the difference between the applied and local magnetic fields in a phenomenon called local diamagnetic shielding. Essentially,...
845
Atomic Nuclei: Magnetic Resonance
639
The number of nuclear spins aligned in the lower energy state is slightly greater than those in the higher energy state. In the presence of an external magnetic field, as the spins precess at the Larmor frequency, the excess population results in a net magnetization oriented along the z axis. When a pulse or a short burst of radio waves at the Larmor frequency is applied along the x axis, the coupling of frequencies causes resonance and flips the nuclear spins of the excess population from the...
639