巨型二极管共振参数的优化和几个球形和变形核的光中子截面计算
概括
这项研究计算了球形和变形核的巨双极共振 (GDR) 参数. 这些参数准确地预测了光中子截面,验证了核物理学中的理论模型.
科学领域:
- 核物理 核物理 核物理
- 光子核反应的反应
- 核结构 核结构
背景情况:
- 巨型双极共振 (GDR) 是了解光子与高达30 MeV的物质相互作用的关键.
- 作为洛伦兹峰值观察到的GDR特征在球形和变形核之间有所不同.
- 对光子诱导反应的精确理论模拟依赖于精确的GDR参数.
研究的目的:
- 为特定的球形和变形同位素计算巨双极共振 (GDR) 参数.
- 在理论反应代码中利用这些计算的GDR参数.
- 通过将预测的光中子截面与实验数据进行比较,验证计算的GDR参数的准确性.
主要方法:
- 优化了实验数据的合适性,以确定包括115In,144Sm,148Sm,150Sm,154Sm,153Eu和160Gd在内的同位素的GDR参数.
- 将计算的GDR参数输入到TALYS 1.8代码中.
- 使用TALYS 1.8代码进行计算的光中子截面.
主要成果:
- 为所选的球形和变形同位素计算的GDR参数.
- 根据计算的GDR参数生成光中子截面.
- 计算的光中子截面与现有的实验数据之间的观察一致性.
结论:
- 计算的GDR参数可用于描述光吸收截面的可靠性.
- 使用获得的GDR参数,TALYS 1.8代码准确模拟了光中子横截面.
- 这项工作验证了用于预测核反应结果的理论方法.
更多相关视频
10:10Neutron Crystallography Data Collection and Processing for Modelling Hydrogen Atoms in Protein Structures
Published on: December 1, 2020
4.9K
10:27Contrast-Matching Detergent in Small-Angle Neutron Scattering Experiments for Membrane Protein Structural Analysis and Ab Initio Modeling
Published on: October 21, 2018
12.3K
相关概念视频
Nuclear Overhauser Enhancement (NOE)
646
Irradiation of a spin-active nucleus causes an increase or decrease in the signal intensity of neighboring nuclei that are not necessarily chemically bonded or involved in J-coupling. This phenomenon, called the Nuclear Overhauser Enhancement (NOE), results from through-space interactions between the nuclear spins. The NOE effect decreases with increasing internuclear distance and is generally not observed beyond 4 angstroms. In NOE, dipole-dipole interactions between neighboring...
646
Atomic Nuclei: Nuclear Relaxation Processes
632
In the absence of an external magnetic field, nuclear spin states are degenerate and randomly oriented. When a magnetic field is applied, the spins begin to precess and orient themselves along (lower energy) or against (higher energy) the direction of the field. At equilibrium, a slight excess population of spins exists in the lower energy state. Because the direction of the magnetic field is fixed as the z-axis, the precessing magnetic moments are randomly oriented around the z-axis.
632
Double Resonance Techniques: Overview
192
Double resonance techniques in Nuclear Magnetic Resonance (NMR) spectroscopy involve the simultaneous application of two different frequencies or radiofrequency pulses to manipulate and observe two distinct nuclear spins. One important application of double resonance is spin decoupling, which selectively suppresses coupling with one type of nucleus while observing the NMR signal from another nucleus, simplifying the spectrum and enhancing resolution.
Spin decoupling is usually achieved by...
Spin decoupling is usually achieved by...
192
NMR Spectrometers: Resolution and Error Correction
679
When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
679
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)
1.0K
When proton-coupled carbon-13 spectra are simplified by a broadband proton decoupling technique, structural information about the coupled protons is lost. Distortionless enhancement by polarization transfer (DEPT) is a technique that provides information on the number of hydrogens attached to each carbon in a molecule. While the DEPT experiment utilizes complex pulse sequences, the pulse delay and flip angle are specifically manipulated. The resulting signals have different phases depending on...
1.0K
Atomic Nuclei: Magnetic Resonance
639
The number of nuclear spins aligned in the lower energy state is slightly greater than those in the higher energy state. In the presence of an external magnetic field, as the spins precess at the Larmor frequency, the excess population results in a net magnetization oriented along the z axis. When a pulse or a short burst of radio waves at the Larmor frequency is applied along the x axis, the coupling of frequencies causes resonance and flips the nuclear spins of the excess population from the...
639