身体位置和袖子尺寸影响下肢动脉封闭压力及其预测因素:在训练中使用血流限制的压力标准化方面的影响
Victor S de Queiros1, Nicholas Rolnick2,3, Okan Kamiş4
1Graduate Program in Health Sciences, Federal University of Rio Grande do Norte (UFRN), Natal, Brazil.
Frontiers in physiology
|August 27, 2024
概括
血流限制运动的动脉封闭压力 (AOP) 测量受袖口尺寸和身体位置的影响. 标准化AOP需要考虑这些因素来准确的运动处方.
科学领域:
- 运动生理学 运动生理学
- 生物医学工程 生物医学工程
背景情况:
- 动脉封闭压力 (AOP) 对于个性化血流限制运动 (BFRE) 是至关重要的.
- 了解影响AOP的因素对于一致的BFRE协议至关重要.
研究的目的:
- 比较下肢AOP (LL-AOP) 使用中等 (11厘米) 和大 (18厘米) 袖口.
- 调查身体位置 (仰卧,坐着,站着) 对LL-AOP的影响.
- 识别不同袖口和位置的LL-AOP测量的预测因素.
主要方法:
- 与51名健康志愿者 (25名男性,26名女性) 进行横截面研究.
- 测量大腿周长和手臂血压.
- 在仰卧,坐着和站着的姿势中使用中型和大型袖口评估LL-AOP.
主要成果:
- 大袖需要较少的外部压力 (mmHg) 阻塞与中袖相比,在所有位置 (p < 0.001).
- 在仰卧姿势下,无论袖口大小如何,LL-AOP显著降低 (p < 0.001).
- 缩血压预测大袖的LL-AOP;大腿周长预测中袖的LL-AOP.
结论:
- LL-AOP及其预测因素受到身体位置和袖口宽度的显著影响.
- 这些变量必须考虑在BFRE协议中标准化压力.
- 调查结果有助于开发更准确的方程来估计LL-AOP.
相关概念视频
Sites for measruring blood pressure
1.6K
Blood pressure measurement is a fundamental clinical procedure, providing crucial data for assessing cardiovascular health. Among the various sites for this measurement, the brachial and popliteal arteries are predominantly utilized due to their accessibility and the reliability of their readings. This lesson delves into the anatomical significance, methodology, and considerations of measuring blood pressure at these locations.
The Brachial Artery: Primary Site for Blood Pressure Measurement
The Brachial Artery: Primary Site for Blood Pressure Measurement
1.6K
Pre-Procedural Guidelines for Assessing Blood Pressure
527
Accurate blood pressure assessment is crucial for diagnosing and managing various health conditions. To ensure the reliability of these measurements, healthcare professionals must adhere to standardized pre-procedural guidelines. These guidelines enhance patient safety and improve the overall quality of healthcare. The following steps are essential for obtaining accurate and consistent blood pressure readings, from using the appropriate tools to ensuring effective communication with the...
527
Assessing Blood pressure in the Leg
2.2K
Proper measurement of leg blood pressure is a critical skill for healthcare providers, ensuring precise and reliable readings. When performed correctly, this procedure informs patient care and enhances the efficacy of interventions. The following text outlines step-by-step guidelines to measure blood pressure in the leg, providing clarity and ease of understanding for practitioners.
Preparation:
Preparation:
2.2K
Special considerations while measuring blood pressure
711
When assessing blood pressure (BP), healthcare professionals must consider various factors and potential unexpected outcomes to ensure accurate readings and provide proper patient care. Adhering to these guidelines is essential to achieving the most reliable results.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
711
Assessment of blood pressure in brachial artery(two-step method)
665
Measuring blood pressure is a fundamental skill in healthcare that aids in diagnosing and monitoring hypertension and other cardiovascular conditions. An aneroid sphygmomanometer, commonly used in clinical settings, offers a manual and precise method for blood pressure measurement. The technique for using this instrument involves specific steps that must be carefully executed to ensure accuracy. The following detailed description outlines a two-step technique for assessing blood pressure using...
665
Assessment of blood pressure in brachial artery(one-step method)
561
This procedural guide systematically measures blood pressure using an oscillometric digital sphygmomanometer, emphasizing accuracy, patient safety, and comfort.
Prepare for the Procedure:
Prepare for the Procedure:
561