使用离子交换膜BII从二进制系统中提升了酸性染料 (AB1和MO) 的去除:动力,同热和热力学分析
Aqsa Naz1, Farrukh Jaleel2, Shagufta Zafar1
1Department of Chemistry, The Government Sadiq College Women University, Bahawalpur, 63100, Pakistan.
Environmental science and pollution research international
|August 27, 2024
概括
阳离子交换膜BII有效地从水中去除酸黑1 (AB1) 和甲基色 (MO) 染料. 这项研究强调了AEM-BII.
科学领域:
- 环境化学环境化学
- 材料科学 材料科学 材料科学
背景情况:
- 酸性染料如酸黑1 (AB1) 和甲基色 (MO) 是常见的工业污染物.
- 从水系统中有效地去除这些染料对于环境保护至关重要.
研究的目的:
- 在二进制系统中研究AB1和MO在离子交换膜BII (AEM-BII) 上的吸附.
- 评估操作参数对染料去除和AEM-BII可重复使用性的影响.
主要方法:
- 使用AEM-BII.II进行了实验性吸附研究.
- 进行了动力学,同热和热力学分析.
- 评估了染料去除效率,吸附剂回收和可重复使用性.
主要成果:
- 在最佳条件下 (150分钟,5克L-1吸附剂) 产生了91.2%的AB1和83.4%的MO去除.
- 吸附遵循伪二次动力学和兰格穆尔等热量.
- 热力学研究表明自发和内热吸附.
结论:
- 在二进制系统中,AEM-BII显示出作为酸性染料的吸附剂的巨大潜力.
- 膜在脱落后具有良好的可重复使用性,可实现74.95%的染料去除.
相关概念视频
Ion Exchange
565
Ion exchange chromatography separates charged molecules from a solution by reversibly exchanging them with mobile, or 'active', ions associated with the oppositely charged stationary phase. This method can be used to separate ions, soften and deionize water, and purify solutions. The polymers comprising the ion-exchange column are high-molecular-weight and chemically stable polymers, crosslinked to be porous and essentially insoluble. They are also functionalized with either acidic or...
565
Dialysis
616
Dialysis is a diffusion-based purification process that separates analyte molecules from a complex matrix. This is accomplished by allowing molecules in the solution to pass through a semipermeable membrane into a liquid on the other side. The membrane is usually made of cellulose acetate or cellulose nitrate, and the second liquid must be miscible with the solution. Ions (e.g., chloride or sodium) or organic molecules (e.g., glucose) can pass through the membrane pores, which generally have...
616
Extraction: Advanced Methods
433
Metal ions can be separated from one another by complexation with organic ligands–the chelating agent– to form uncharged chelates. Here, the chelating agent must contain hydrophobic groups and behave as a weak acid, losing a proton to bind with the metal. Since most organic ligands used in this process are insoluble or undergo oxidation in the aqueous phase, the chelating agent is initially added to the organic phase and extracted into the aqueous phase. The metal-ligand complex is...
433
Extraction: Effects of pH
455
Consider a neutral form of an amine, B, with a partition coefficient, K, in a liquid mixture containing organic and aqueous phases. The pH of the aqueous phase affects the charge on acidic and basic solutes, and the charged form is usually more soluble in the aqueous phase. Suppose the conjugate acid form of the amine is soluble only in the aqueous phase while the base form is soluble in both phases. Then the distribution coefficient, D, can be given as the ratio of amine concentration in the...
455
Detergent Purification of Membrane Proteins
5.1K
Detergents are used to purify the integral proteins of the membrane. The hydrophobic portion of the detergent can replace membrane phospholipids while solubilizing the membrane proteins. When detergent monomers reach a specific concentration in a solution called critical micelle concentration (CMC), they form micelles. Above CMC, the concentration of the detergent monomers remains in equilibrium with the micelle. The number of detergent monomers present in the CMC varies for each detergent, and...
5.1K
Optimizing Chromatographic Separations
353
Optimizing chromatographic separations is crucial for obtaining clean separations in a minimum amount of time. Optimization is required for several factors, including kinetic effects related to band broadening, plate height, capacity factor, and separation factor.
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
353


