钻石和有机闪探测器的特征使用辐射源用于连续等离子体运行
The Review of scientific instruments
|August 28, 2024
概括
本研究详细介绍了钻石和EJ-309/stilbene探测器的中子校准方法,重点关注n-γ歧视. 结果显示,在等离子体实验期间中子信号采集方面存在很好的一致性.
科学领域:
- 核仪器和探测器的核仪器和探测器
- 等离子体物理学 诊断 诊断
- 辐射检测和测量 辐射检测和测量
背景情况:
- 精确的中子检测对于融合能源研究和核安全至关重要.
- 中子-马 (n-γ) 区分对于混合辐射场的可靠测量至关重要.
- 钻石和有机闪器 (EJ-309, stilbene) 是对中子检测有希望的.
研究的目的:
- 对钻石和闪光探测器的中子校准方法进行全面研究.
- 评估这些探测器的n-γ区分能力.
- 在等离子体环境中验证探测器性能 (ST40实验).
主要方法:
- 脉冲高度分析和脉冲形状歧视 (PSD) 用于信号表征.
- 使用-60 (60Co) 和加利福尼亚-252 (252Cf) 辐射源进行校准.
- 在ST40实验中对钻石探测器与激活进行交叉校准.
主要成果:
- 通过脉冲高度和PSD成功描述了中子和玛相互作用.
- 在ST40等离子射击期间,钻石和闪光探测器之间在中子信号采集方面达成良好协议.
- 钻石探测器和薄膜测量了可比的中子流量 (≈10^6 cm^-2 s^-1),差异约25%.
结论:
- 研究的探测器表现出有效的n-γ区分能力.
- 钻石和闪探测器适用于等离子实验中的中子诊断.
- 交叉校准提供了一种可靠的流量测定和检测器验证方法.
更多相关视频
相关概念视频
Gas Chromatography: Types of Detectors-II
346
In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...
346
Atomic Emission Spectroscopy: Instrumentation
350
The instrumentation of atomic emission spectrometry (AES) involves various components, including atomization devices that convert samples into gas-phase atoms and ions. There are two main types of atomization devices: continuous and discrete atomizers. Continuous atomizers, like plasmas and flames, introduce samples in a constant stream, while discrete atomizers inject individual samples using syringes or autosamplers. The most common discrete atomizer is the electrothermal atomizer.
350
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
201
Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
201
Gas Chromatography: Types of Detectors-I
389
There are different types of detectors used in gas chromatography, each with its own specific properties that make it suitable for detecting certain types of analytes. The most commonly used detectors in GC are thermal conductivity detector (TCD), flame ionization detector (FID), and electron capture detector (ECD).
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
389
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
555
Inductively coupled plasma (ICP) is the most widely used plasma source in atomic emission spectroscopy (AES), also known as Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES). The ICP source, or torch, consists of three concentric quartz tubes with argon gas flowing through them. A spark from a Tesla coil initiates the ionization of argon, generating a high-temperature plasma.
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
555
Atomic Emission Spectroscopy: Lab
151
AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...
151