通过强力和温度敏感监测装置评估头盔的合规性:一项案例对照研究
Francesca Cremonini1, Ariyan Karami Shabankare1, Daniela Guiducci1
1Postgraduate School of Orthodontics, University of Ferrara, Via Luigi Borsari 46, 44121 Ferrara, Italy.
Bioengineering (Basel, Switzerland)
|August 29, 2024
概括
在II类恶性闭塞患者中,平均每天服戴头盔的时间为6.7小时,低于规定的13小时. 虽然对监测的认识显示出轻微的益处,但年轻的患者表现出更好的坚持.
科学领域:
- 矯正牙科 矯正牙科是一種矯正牙科.
- 生物医学工程 生物医学工程
背景情况:
- 顺应正牙治疗对于成功的结果至关重要.
- 需要对头盔使用进行客观监测,以准确评估其坚持性.
研究的目的:
- 客观地评估II类坏闭塞患者的头盔合规性.
- 评估监测意识,治疗持续时间,性别和年龄对合规性的影响.
主要方法:
- 22 患有II类缺陷的患者在3个月内使用了带有Smartgear监控系统的头盔.
- 11名患者被告知监测; 11人没有.
- 数据分析使用R进行统计估计和假设测试.
主要成果:
- 平均每日遵守时间为6.7小时,远远少于规定的13小时.
- 被告知监测的患者每天合作时间增加了1.1小时.
- 年轻的患者 (≤10岁) 的每日合作时间比老年患者多了近2小时.
- 合作率在第一个月更高,主要发生在晚上.
结论:
- 头盔的服从性仍然不足以达到最佳水平,特别是在年轻的患者中.
- 意识到监测可能会提供轻微的,临床上显著的改善遵守.
- 智能装备系统为牙医提供了关于患者遵守的有价值的客观数据.
相关概念视频
Assessing Body Temperature - Temporal Artery
534
Here is a stepwise guide to assessing the body temperature at the temporal artery using a temporal artery thermometer
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
534
Assessing Body Temperature - Tympanic membrane
569
Assessing tympanic membrane temperature involves using a tympanic membrane thermometer (TMT). Here is a step-by-step guide:
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
569