基于YOLOv8和改进的LinkNet的指针计读数方法
Xiaohu Lu1, Shisong Zhu1, Bibo Lu1
1School of Computer Science and Technology, Henan Polytechnic University, Jiaozuo 454003, China.
Sensors (Basel, Switzerland)
|August 29, 2024
概括
本研究介绍了一种改进的LinkNet模型,用于高效的指针计数读数. 该方法提高了自动计量器读取应用程序的准确性和速度.
科学领域:
- 计算机视觉 计算机视觉
- 机器学习 机器学习
背景情况:
- 指针计的读数可能是低效的,容易出现错误.
- 自动阅读系统需要强大的图像处理技术.
研究的目的:
- 开发一种准确和高效的自动指针计数器读数方法.
- 为了提高分段和角度预测的性能,用于仪表读数.
主要方法:
- 使用YOLOv8进行计数器拨号检测.
- 实施了一种改进的LinkNet,具有部分卷积和注意力机制 (CBAM,AFF).
- 采用分类和回归方法来准确预测旋转角度.
主要成果:
- 达到0.20的平均绝对误差的计数器读数.
- 达到每秒15的处理率.
- 证明了增强的特征提取和减少模型大小.
结论:
- 提出的基于LinkNet的方法显著提高了指针计读数的准确性和效率.
- 部分卷积,注意模块和精细的角度预测的集成有助于强大的性能.
更多相关视频
相关概念视频
Electronic Distance Measuring Instruments
30
Electronic Distance Measuring Instruments (EDMs) are essential tools in modern surveying, offering precise distance measurements by emitting electromagnetic signals and calculating the time required for these signals to travel to a target and return. Two primary types of signals are used in EDMs — light waves and microwaves — each suited to specific environmental and distance requirements. Light-wave-based EDMs utilize either infrared or laser light, providing high accuracy over short...
30
Distance Measurements by Taping
30
Tapes are essential in surveying for accurate, durable, and short-distance measurements. Made from lightweight, nylon-coated steel, they offer flexibility and strength for rugged outdoor use. The nylon coating protects against rust and wear, extending the tape's life. Standard lengths, around 30 meters, are marked in meters and millimeters for precision.Surveyors select tapes based on site conditions and accuracy needs. Lightweight, nylon-coated tapes are commonly used for ease of handling and...
30
Ammeter
2.1K
An ammeter is a current measuring instrument. In the circuit, it is represented by the symbol A. The ammeter is placed in series with the device or component to measure the current. A series connection is used because objects in series have the same current passing through them. If a circuit has multiple resistors and the current needs to be measured in each resistor, the number of ammeters required depends on whether the circuit is in series or parallel.
When an ammeter is used to measure the...
When an ammeter is used to measure the...
2.1K
Reducing Line Loss
150
In a three-phase circuit, line loss is an indicator of energy dissipated as heat due to the resistance of transmission lines. To address this, incorporating transformers into the system—a step-up transformer at the source and a step-down transformer at the load—is a strategic solution. Two three-phase transformers are introduced to improve this.
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...
150
The Y-to-Y Circuit
405
In a balanced four-wire wye-to-wye system, the arrangement involves wye-connected sinusoidal voltage sources and loads, connected through a neutral wire that links the neutral nodes of the source and load. The load impedance is connected across each phase of the load. The wye-connected source can be connected to the wye-connected load in four-wire and three-wire arrangements. A three-phase system is considered balanced when the load on each phase is equal, leading to uniform current flow and...
405
Coulometry: Overview
1.1K
Coulometry is one of the rapid, most accurate, and precise analytical techniques that determine the quantity of an analyte by measuring the electrical charge needed for its complete electrolysis without using any analytical standards. The total charge passed during electrolysis correlates with the analyte amount by Faraday's laws of electrolysis. For accurate coulometric measurements, a charge equal to Faraday's constant multiplied by the number of electrons involved in the relevant...
1.1K