概括
这一注释纠正了之前发表在Optics Letters上的文章. 校正确保了光学研究科学记录的准确性.
科学领域:
- 光学和光子学 在光学和光子学.
背景情况:
- 准确的科学记录对于研究的完整性至关重要.
- 以前的出版需要修正.
研究的目的:
- 为已发表的文章提供纠正.
- 确保科学文献的准确性.
主要方法:
- 出版商的审查和验证过程.
- 发行一个正式的出版商的说明.
主要成果:
- 已发布了对Opt.的纠正. 拉脱维亚语 拉脱维亚语 拉脱维亚语 49,2473 (2024年) 的人口.
- 纠正的文章的数字物体标识符 (DOI) 是10.1364/OL.521866.
结论:
- 科学记录现在更新了正确的信息.
- 这确保了光学研究的持续可靠性.
相关概念视频
IR Spectroscopy: Molecular Vibration Overview
2.0K
When Infrared (IR) radiation passes through a covalently bonded molecule, the bonds transition from lower to higher vibrational levels. The fundamental vibrational motions that result in infrared absorption can be classified as stretching or bending vibrations.
Stretching vibrations are vibrational motions that occur along the bond line, changing the bond length or distance between two bonded atoms. They are further distinguished as symmetric or asymmetric. In symmetric stretching, the...
Stretching vibrations are vibrational motions that occur along the bond line, changing the bond length or distance between two bonded atoms. They are further distinguished as symmetric or asymmetric. In symmetric stretching, the...
2.0K
¹³C NMR: ¹H–¹³C Decoupling
1.1K
The probability of having two carbon-13 atoms next to each other is negligible because of the low natural abundance of carbon-13. Consequently, peak splitting due to carbon-carbon spin-spin coupling is not observed in spectra. However, protons up to three sigma bonds away split the carbon signal according to the n+1 rule, resulting in complicated spectra.
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
1.1K
UV–Vis Spectroscopy: Woodward–Fieser Rules
24.0K
UV–Visible absorption spectra of conjugated dienes arise from the lowest energy π → π* transitions. The light-absorbing part of the molecule is called the chromophore, and the substituents directly attached to the chromophore are called auxochromes. A strong correlation exists between the absorption maxima, λmax, and the structure of a conjugated π system. The Woodward–Fieser rules predict the value of λmax for a given...
24.0K
Molecular Spectroscopy: Absorption and Emission
1.9K
Molecules possess discrete energy levels called quantum states. Unlike atoms, which have simpler energy levels, molecules possess additional rotational and vibrational energy levels. Each energy level is separated by an energy gap, with the gaps between adjacent electronic, vibrational, and rotational levels varying significantly. The three types of energy levels in a diatomic molecule are shown in Figure 1.
1.9K
UV–Vis Spectroscopy: Molecular Electronic Transitions
1.4K
In Ultraviolet–Visible (UV–Vis) spectroscopy, the absorption of electromagnetic radiation is used to probe the electronic structure of molecules. This technique provides insights into molecular electronic transitions, particularly the movement of electrons between different molecular orbitals. Radiation is absorbed if the energy of the electromagnetic radiation passing through the molecule is precisely equal to the energy difference between the excited and ground states. During this...
1.4K
Ultraviolet and Visible (UV–Vis) Spectroscopy: Overview
2.5K
Ultraviolet–visible (UV–visible or UV–Vis) spectroscopy is an analytical technique that investigates the interaction between matter and UV–Vis light within the electromagnetic spectrum. This method is widely used for its versatility, simplicity, and relatively quick data acquisition, making it valuable for both qualitative and quantitative analysis. When UV–Vis radiation passes through a material, molecules absorb light depending on the energy required for...
2.5K


