在油转中的旋转器故障的ResNet诊断
Lei Chen1, Liang Dong1, Zhi-Cai Wu1
1Research Center of Fluid Machinery Engineering and Technology, Jiangsu University, Zhenjiang, Jiangsu, 212013, China.
Heliyon
|September 3, 2024
概括
使用剩余网络 (ResNet) 的新诊断框架可以准确检测油中转子故障. 最佳的传感器放置和信号处理显著提高了诊断准确度,提高了操作可靠性.
科学领域:
- 机械工程 机械工程
- 人工智能的人工智能
- 状态监控 状态监控
背景情况:
- 转子不平衡和错位是转油的关键问题,影响运行效率和安全.
- 有效的诊断方法对于早期故障检测和防止灾难性故障至关重要.
研究的目的:
- 开发一种创新的诊断框架,用于识别转子失衡和油转中的错位.
- 通过先进的信号处理和战略性传感器放置来提高诊断效率.
主要方法:
- 一个剩余网络 (ResNet) 模型被用于故障诊断.
- 从八个测量点捕获振动信号,使用故障模拟测试装置进行测试.
- 使用了一维和多维信号处理技术,包括短时间里埃转换 (STFT).
- 传感器的位置在轴承座位的轴向,进口边的垂直方向和出口边的轴向方向上进行了优化.
主要成果:
- 拟议的ResNet框架实现了对旋翼故障的诊断准确度超过98%.
- 最佳的传感器放置显著增加了对旋转器故障的灵敏度.
- 通过STFT处理的时间频率数据产生了最高的诊断准确度.
结论:
- 最佳的信号处理和精确的传感器放置对于精确的转子故障诊断在油转中至关重要.
- 开发的框架提高了能源传输系统的运行可靠性和效率.
- 这项研究为旋转机械的状态监测提供了一个强大的方法.
相关概念视频
Node Analysis for AC Circuits
300
Consider an angioplasty system featuring a catheter equipped with a turbine, a critical tool for removing plaque deposits from coronary arteries. This intricate medical device operates using a circuit model reminiscent of a dual-node RLC circuit powered by a current-controlled voltage source.
To unravel the complexities of this system, nodal analysis is employed, a powerful technique founded on Kirchhoff's current law (KCL), which remains valid for phasors. AC circuits can effectively be...
To unravel the complexities of this system, nodal analysis is employed, a powerful technique founded on Kirchhoff's current law (KCL), which remains valid for phasors. AC circuits can effectively be...
300
Radial System Protection
92
Radial systems employ time-delay overcurrent relays to reduce load interruptions. When a fault occurs, the nearest breaker opens first, while upstream breakers remain closed due to longer delay settings. This approach ensures minimal disruption to the rest of the system.
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
92
Sequence Networks of Rotating Machines
98
A Y-connected synchronous generator, grounded through a neutral impedance, is designed to produce balanced internal phase voltages with only positive-sequence components. The generator's sequence networks include a source voltage that is exclusively in the positive-sequence network. The sequence components of line-to-ground voltages at the generator terminals illustrate this configuration.
Zero-sequence current induces a voltage drop across the generator's neutral impedance and other...
Zero-sequence current induces a voltage drop across the generator's neutral impedance and other...
98
Directional Relays
103
Directional relays, essential for managing unidirectional fault currents, enhance the safety and efficiency of power systems. On power lines equipped with directional relays, faults downstream (to the right) of the current transformer typically cause the fault current to lag the bus voltage by approximately 90 degrees, known as the forward direction. In contrast, upstream (left-side) faults may result in the fault current leading the bus voltage by nearly 90 degrees, termed the reverse...
103
Three-Phase Short Circuit—Unloaded Synchronous Machine
132
Conducting a three-phase short circuit test on an unloaded synchronous machine helps understand its impact on the system. The AC fault current's oscillogram, with the DC offset removed, reveals that the waveform amplitude decreases from an initially high value to a steady-state level for one phase of the machine.
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
132
Differential Relays
117
Differential relays are used to protect generators, buses, and transformers by comparing electrical quantities at different points. When a fault occurs, the difference in current between the two points triggers the relay to operate, opening the circuit breaker. Under normal conditions, the current entering (i1) and leaving (i2) a generator are equal. When a fault occurs, however, these currents become unequal, and the difference current flows in the relay operating coil, causing the relay to...
117