在患有大动脉狭窄症的患者中,通过超多普勒测量心内流动力学的变化
Jolanda Sabatino1,2,3,4, Isabella Leo1,3, Antonio Strangio1,3
1Department of Experimental and Clinical Medicine, Magna Graecia University, Catanzaro, Italy.
European heart journal open
|September 4, 2024
概括
大动脉狭窄 (AS) 显著改变心内流动的动态,增加的深度和强度. 通过超多普勒测量这些变化,可以帮助区分AS患者与健康个体以及心室重塑患者.
科学领域:
- 心血管医学 心血管医学
- 生物医学工程 生物医学工程
- 流体动力学 流体动力学
背景情况:
- 心脏内流动的动态对于心脏健康至关重要.
- 心脏异常,包括大动脉狭窄 (AS),与改变的旋流模式有关.
- 量化心内旋可能提供新的诊断见解.
研究的目的:
- 为了研究严重的大动脉狭窄 (AS) 对心内旋动态的影响.
- 探索评估AS患者心内流动动态的临床实用性.
- 为了确定流体动力学测量是否可以区分AS与其他心脏状况.
主要方法:
- 前性研究包括120名严重AS患者,60名心室重塑 (VR) 患者和100名对照患者 (CTRL).
- 使用超多普勒技术与标准心声回声学一起进行心内流动动力学的非侵入性评估.
- 分析的参数 (深度,长度,强度,面积) 和能量消耗.
主要成果:
- 与对照组相比,AS患者的深,长度,强度和面积显著增加 (P < 0.001).
- 与对照组相比,AS患者的平均能量消耗显著更高 (P < 0.001) 和VR患者 (P = 0.002).
- 状深度显示出识别AS的最高诊断能力 (P < 0.001).
结论:
- 超多普勒对心内流动动态的评估在AS患者中可靠.
- 深度和强度的量化变化可以区分AS与VR和健康对照.
- 心内流动动力学评估为患者分层提供了标准心声回声学的补充信息.
更多相关视频
09:24O-Ring Aortic Banding Versus Traditional Transverse Aortic Constriction for Modeling Pressure Overload-Induced Cardiac Hypertrophy
Published on: October 6, 2022
3.4K
06:39Ultrasound Based Assessment of Coronary Artery Flow and Coronary Flow Reserve Using the Pressure Overload Model in Mice
Published on: April 13, 2015
14.9K
相关概念视频
Assessing Blood pressure using a doppler ultrasound
1.2K
To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
1.2K
Equipments Used To Measure Blood Pressure
853
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
853