看到心:超声波如何改善医疗决策
Jared L Cohen1, Amie Billstrom2, Melissa Myers2
1Emergency Department, San Antonio Military Medical Center, San Antonio, USA.
Cureus
|September 4, 2024
概括
护理点超声波 (POCUS) 可以帮助急诊医生快速识别心脏壁运动异常. 这种快速评估有助于诊断心脏紧急情况,并改善关键情况下的患者护理.
科学领域:
- 紧急医疗 紧急医疗
- 心脏病学 心脏病学
- 护理中心超声波检查
背景情况:
- 新发作的心脏节律失常症具有广泛的差异诊断.
- 快速识别心脏紧急情况对于患者的生存至关重要.
- 声心成像对于诊断心脏疾病至关重要.
研究的目的:
- 评估点照顾超声波 (POCUS) 在识别区域墙壁运动异常方面的实用性.
- 评估POCUS如何加速为紧急医疗 (EM) 医生提供以患者为中心的护理.
- 确定POCUS是否可以帮助EM医生管理高风险心脏病例.
主要方法:
- 审查POCUS在紧急医疗中的应用.
- 分析回声心脏学原理,用于检测墙壁运动异常.
- 在新出现的心律失常情景中使用POCUS的案例研究审查.
主要成果:
- 通过POCUS识别区域墙壁运动异常对于EM医生来说是可行的.
- 在心脏紧急情况下,POCUS可以提供快速,可操作的信息.
- 这种技术可以补充传统的诊断方法.
结论:
- POCUS是紧急医疗医生评估心脏功能的一个有价值的工具.
- 使用POCUS早期识别墙壁运动异常可以改善患者的治疗结果.
- 将POCUS整合到核心EM心电回声学实践中,需要进一步考虑.
相关概念视频
Decreased pulse rate
536
Bradycardia is a medical condition in which the heart rate is slower than normal. It occurs when the heart's natural pacemaker, the sinus node, generates slower electrical impulses than the standard rhythm. In adults, bradycardia is diagnosed when the pulse rate falls below 60 beats per minute, indicating a deviation from the normal heart rate range.
There are specific risk factors that can elevate the likelihood of developing bradycardia. Advanced age is a significant factor, with...
There are specific risk factors that can elevate the likelihood of developing bradycardia. Advanced age is a significant factor, with...
536
Assessing Blood pressure using a doppler ultrasound
1.2K
To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
1.2K
Imaging Studies for Cardiovascular System I:Echocardiography
303
Cardiac imaging studies encompass a wide range of noninvasive and minimally invasive techniques designed to visualize the heart's structure and function in detail. One such technique is echocardiography, which uses high-frequency ultrasound waves to produce detailed images of the heart, known as echocardiograms.
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
303
Pulse rhythm
775
Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
775
Ultrasonography
4.4K
Ultrasonography is an imaging technique that uses high-frequency sound waves to visualize the body's internal structures. It is a non-invasive and safe procedure that does not involve the use of ionizing radiation, making it widely used in various medical fields. Ultrasonography is used to study heart function, blood flow in the neck or extremities, certain conditions such as gallbladder disease, and fetal growth and development.
During an ultrasonography procedure, a handheld device called...
During an ultrasonography procedure, a handheld device called...
4.4K
Equipments Used To Measure Blood Pressure
853
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
853