使用周期性IMS-MS对PS改性合成寡核酸的二聚体特性鉴定
Edie M Sharon1, Sarah M O'Keefe1, Kathleen T Grassmyer2
1Department of Chemistry, Indiana University, Bloomington, Indiana 47401, United States.
Analytical chemistry
|September 9, 2024
概括
鉴定酸 (PS) 改性寡核酸的特征对于药物开发至关重要. 这项研究引入了一种新型的循环离子移动性光谱-并联质谱法 (IMS-MS) 方法,用于在没有酶消化的情况下分析PS寡核酸二聚体.
科学领域:
- 橄核酸的治疗药物
- 分析化学是一种分析化学.
- 质谱测量质量谱测量
背景情况:
- 合成的寡核酸是基因表达调节的有价值的治疗药物.
- 酸 (PS) 连接增强了寡核酸的稳定性和性能.
- PS的修改会产生复杂的二聚体混合物,这给分析带来了挑战.
研究的目的:
- 开发和演示一种分析方法来表征PS改性寡核酸中的二聚体.
- 解决目前缺乏用于测量PS寡核酸二聚体的方法的问题.
主要方法:
- 在完整的寡核酸上利用循环离子移动性光谱-并联质谱 (IMS-MS).
- 在MS中采用了自上而下的碎片化,以产生更小的碎片和更少的二聚体.
- 应用串联IMS用于终端二极体的基于移动性的分辨率.
主要成果:
- 成功阐明了四种模型PS修饰的寡核酸中的二聚体结构.
- 证明IMS-MS能够在没有酶消化的情况下分析完整的寡核酸.
- 展示了碎片末端的二聚体的移动性分辨率.
结论:
- 开发的循环IMS-MS方法为表征PS寡核酸二体提供了一个强大的工具.
- 这种技术有助于更深入地了解用于治疗的修改过的寡核酸结构.
- 该方法克服了现有的PS改性疗法分析技术的局限性.
相关概念视频
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)
1.0K
When proton-coupled carbon-13 spectra are simplified by a broadband proton decoupling technique, structural information about the coupled protons is lost. Distortionless enhancement by polarization transfer (DEPT) is a technique that provides information on the number of hydrogens attached to each carbon in a molecule. While the DEPT experiment utilizes complex pulse sequences, the pulse delay and flip angle are specifically manipulated. The resulting signals have different phases depending on...
1.0K
High-Resolution Mass Spectrometry (HRMS)
1.3K
The resolution of a mass spectrometer depends on the efficiency of separating ions with different ion masses. The mass of an atom is approximated to the sum of the masses of protons and neutrons inside, considering the masses of protons and neutrons as equal. However, the masses of the proton (1.6726 × 10−24 g) and neutron (1.6749 × 10−24 g) are not truly equal. There is a minor error in the expression of atomic masses relative to the simplest atom of hydrogen. For...
1.3K
Mass Spectrometry: Complex Analysis
736
Mass spectrometry is an important technique for the identification of pure compounds. However, it has some limitations for the analysis of complex mixtures, often due to excessive fragmentation making the spectrum too complicated to decipher. Mass spectrometry can be combined with suitable separation methods in sequence, forming hyphenated methods, which are useful in the analysis of complex mixtures.
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
736
Chemical Ionization (CI) Mass Spectrometry
710
The molecular ion peak of a molecule in the mass spectrum provides vital information for molecular identification. However, conventional electron impact ionization can lead to the rapid dissociation of some molecular ions before they reach the detector. A milder ionization method is required to increase the lifetime of such ionized analyte molecules. Chemical ionization (CI) is a gas-phase protonation reaction useful for mass-analyzing analyte molecules that are easily protonated to yield the...
710
Mass Spectrometry: Overview
4.7K
Mass spectrometry is an analytical technique used to determine the molecular mass and molecular formula of a compound. The basic principle of mass spectrometry is to generate ions from the analyte molecule and measure these ion abundances against their molecular mass. One common type of ionization, known as electrospray ionization or EI, bombards the analyte molecules in the gas phase with high-energy electron beams. The electron beams displace an electron from the molecule and leave...
4.7K
Mass Spectrometry: Isotope Effect
2.0K
Most elements exist in nature as a mixture of isotopes. The isotopes differ in weight due to their respective number of neutrons. The molecular weight of a molecule is different depending on the specific isotope of its elements involved. As a result, the mass spectrum of the molecule exhibits peaks from the same fragment at multiple positions. The positions of these mass signals depend on the difference between the molecular mass. Furthermore, the intensity of these signals is dependent on the...
2.0K