使用动态场维恩波器用大量选择的离子写作
Michael F Espenship1, Julia Laskin1
1James Tarpo Jr. and Margaret Tarpo Department of Chemistry, Purdue University, West Lafayette, Indiana 47907, United States.
Journal of the American Society for Mass Spectrometry
|September 10, 2024
概括
研究人员开发了一种低成本的维恩波器,用于精确的离子沉积. 该设备可实现对量选择离子的平行,一维和二维表面图案,用于先进的接口制造.
科学领域:
- 物理 物理学 物理
- 材料科学 材料科学 材料科学
- 表面科学是一门学科.
背景情况:
- 离子软着陆对于制造具有受控分子沉积的接口至关重要.
- 现有的对大质量选择离子进行图案的方法可能是复杂和昂贵的.
研究的目的:
- 设计和实施一个低成本的维恩波器,用于先进的离子表面图案.
- 为了证明质量选择的离子的并行沉积和一维和二维图案.
主要方法:
- 使用强大的永久磁铁构建维恩过器.
- 集成到一个离子软着陆仪器中.
- 动态电场 (与磁场平行和直角) 的应用用于离子操纵.
主要成果:
- 成功地将离子从多组件,高流量离子束中分离出来.
- 具有不同质量电荷比的离子同时沉积.
- 通过电场参数控制的一维阵列模式的演示.
- 在保持质量分离的同时,实现了二维表面图案.
结论:
- 开发的低成本维恩波器是控制离子沉积的实用工具.
- 允许用于界面工程的质量选择离子的多功能表面图案.
- 为制造复杂的离子接口提供了具有成本效益的解决方案.
相关概念视频
Mass Analyzers: Common Types
579
The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
579
Electrospray Ionization (ESI) Mass Spectrometry
750
Higher molecular weight biomolecules are nonvolatile compounds that may decompose before ionizing or vaporizing during mass analysis with conventional electron impact ionization methods. Accordingly, electrospray ionization (ESI) is the favored method for vaporizing and ionizing biomolecules as it circumvents rapid fragmentation and enables the recording of mass signals for the entire biomolecule.
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
750
Mass Spectrometers
5.2K
This lesson details the instrumentation of a mass spectrometer—a physical instrument to perform mass spectrometry on analyte molecules and record the characteristic mass spectra. This is achieved via three chief functions:
5.2K
Mass Analyzers: Overview
615
The mass analyzer is a crucial component of the mass spectrometer. In the ionization chamber, the vaporized sample is bombarded with a high-energy electron beam to generate a radical cation and further fragment into neutral molecules, radicals, and cations. A series of negatively charged accelerator plates accelerate the cations into the mass analyzer. The mass analyzer separates ions according to their mass-to-charge (m/z) ratios and then directs them to the detector. The common types of mass...
615
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
662
In inductively coupled plasma–mass spectrometry (ICP–MS), an inductively coupled plasma (ICP) torch is used as an atomizer and ionizer. Solid samples are dissolved and volatilized before being introduced into the high-temperature argon plasma, while solution samples are nebulized and passed through the high-temperature argon plasma. Plasma dissociates the analytes and ionizes their component atoms to form a mixture of positive ions and molecular species. The positive ions are then...
662
Ion-Exchange Chromatography
397
Ion-exchange chromatography, or IEC, is a technique for separating ions based on their affinity for the stationary phase. The stationary phase is a cross-linked polymer resin with covalently attached ionic functional groups. The functional groups can be either positively charged (cation exchangers) or negatively charged (anion exchangers). A cation exchanger consists of a polymeric anion and active cations, while an anion exchanger is a polymeric cation with active anions. The choice of...
397