实验研究关于通过织物增强的水泥基层对钢筋混凝土梁的剪切强化
Chanseo Jung1, Yujae Seo2, Junseo Hong1
1Department of Architecture and Architectural Engineering, Hankyong National University, Jungang-ro 327, Anseong 17579, Republic of Korea.
Materials (Basel, Switzerland)
|September 14, 2024
概括
面料增强型水泥模板 (FRCM) 显著提高了钢筋混凝土 (RC) 梁的剪切强度,而无需剪切增强. FRCM还有助于控制RC梁的变形,改善整体结构性能.
科学领域:
- 土木工程 土木工程是指土木工程.
- 材料科学 材料科学 材料科学
背景情况:
- 钢筋混凝土 (RC) 梁容易发生剪切故障.
- 织物增强水泥基板 (FRCM) 为加强现有结构提供了一个潜在的解决方案.
研究的目的:
- 调查用FRCM加强的RC梁的剪切性能.
- 使用数字图像相关性 (DIC) 分析强化束的变形特征.
- 开发和验证FRCM强化RC梁的剪切强度模型.
主要方法:
- 实验测试四个RC光束 (一个控制,三个加强).
- 应用数字图像关联 (DIC) 技术来监测光束变形.
- 剪切应变-剪切应力曲线和主要应变角度变化的分析.
主要成果:
- 在没有剪切增强的梁中,FRCM增强增加了高达65%的剪切强度.
- 由DIC数据证明的FRCM控制的光束变形.
- 一个拟议的切削强度模型合理地评估了FRCM增强的RC光束性能.
结论:
- FRCM是一种有效的强化技术,用于提高RC梁的剪切能力.
- 拟议的模型提供了一种可靠的方法来预测FRCM增强RC梁的剪切强度.
- FRCM有助于提高RC元件的结构完整性和变形控制.
相关概念视频
Fiber Reinforced Concrete
71
Fiber-reinforced concrete significantly enhances the structural and nonstructural properties of traditional concrete by incorporating fibers like steel, glass, and polymers. These fibers, varying from natural ones such as sisal and cellulose to manufactured ones like polypropylene and Kevlar, are mixed into hydraulic cement with aggregates. Steel fibers, often preferred for their robustness, contribute to improved ductility, toughness, and post-cracking performance. The concrete is classified...
71
Reinforcements in Concrete
80
Reinforced concrete is a composite material used extensively in construction, combining the compressive strength of concrete with the tensile strength of steel. This synergy is essential as concrete, while excellent at resisting compression, is weak under tension. Steel bars, or rebars, are embedded in the concrete to handle these tensile forces. The choice of steel is strategic; it shares a similar coefficient of thermal expansion with concrete, which ensures uniformity in response to...
80
Design Example: Distributing Reinforcements in Concrete Sections
83
The topic explores the practical aspects of adjusting steel reinforcements within a concrete beam section to meet specific design requirements. When designing a reinforced concrete beam, it is essential to distribute the steel reinforcements properly to ensure structural integrity and efficiency. The example provided details a scenario where a beam requires a total steel cross-section of 4 square inches. The engineer identifies that the available steel bars have a nominal diameter of 1.693...
83
Shearing Stresses in a Beam: Problem Solving
173
A cantilever beam with a rectangular cross-section under distributed and point loads experiences shearing stresses. The analysis begins by identifying the loads acting on the beam. Then, the reactions at the beam's fixed end are calculated using equilibrium equations. The vertical reaction is a combination of the distributed and point loads, while the moment reaction is the sum of their moments. The shear force distribution along the beam, resulting from these loads, is established by...
173
Tensile Strength Considerations of Concrete
118
Considering the tensile strength of concrete involves recognizing that the theoretical strength of cement paste can be up to a thousand times higher than what is observed in practical applications. This significant discrepancy is largely attributed to the presence of microscopic cracks within the concrete. These cracks tend to amplify stress at their tips when a load is applied, a phenomenon explained by Griffith's theory of brittle fracture.
The dimensions and shape of a concrete specimen...
The dimensions and shape of a concrete specimen...
118
Strength of Cement
127
Strength tests for cement are not performed directly on neat cement paste due to difficulty in obtaining consistent, reliable specimens. Instead, cement is typically tested in the form of cement-sand mortar.
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
127