一个定制的热发光和放射发光光谱学综合系统
Matheus C S Nunes1, Miguel L Rodrigues2, Walace J R Silva3
1Instituto de Física, Universidade de São Paulo (USP), São Paulo SP, Brazil; Instituto de Ciência e Tecnologia, Universidade Estadual Paulista (UNESP), Sorocaba, SP, Brazil.
概括
开发了一个新的集成系统,LUMI22,用于热发光 (TL) 和辐射发光 (RL) 测量. 该系统准确地从众所周知的光物中测量了TL和RL,证实了其用于剂量测量应用的功能.
科学领域:
- 物理 物理学 物理
- 材料科学 材料科学 材料科学
- 仪器化 仪器化 仪器化
背景情况:
- 热发光 (TL) 和辐射发光 (RL) 是剂量计中的关键技术.
- 现有的系统可能缺乏综合功能,用于全面的TL和RL分析.
研究的目的:
- 介绍一个定制的集成系统,LUMI22,用于先进的TL和RL测量.
- 为了验证系统的性能,使用具有良好特征的光体.
主要方法:
- 开发了带有Kanthal® A1加热系统和微控制器控制温度的LUMI22.
- 使用X射线管进行照射,使用光倍增管 (PMT) 和光纤光谱仪进行光检测.
- 从Al2O3:C,Mg,Al2O3:C和TLD-100光物中测量了TL和RL.
主要成果:
- LUMI22系统成功测量了TL和RL,包括光谱分析.
- 从标准体获得的TL和RL数据与已发表的结果有很好的一致性.
- 该系统在剂量测量研究中表现出可靠的性能.
结论:
- 定制的LUMI22系统是TL和RL测量的功能和多功能工具.
- 这一集成系统提升了辐射检测和材料表征的能力.
- LUMI22为剂量测量研究和应用提供了一个可靠的平台.
相关概念视频
Photoluminescence: Applications
383
Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...
383
Raman Spectroscopy Instrumentation: Overview
298
A conventional Raman spectrophotometer includes a laser source, a sample holding system, a wavelength selector, and a detector.
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
298
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
199
Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
199
Atomic Emission Spectroscopy: Instrumentation
346
The instrumentation of atomic emission spectrometry (AES) involves various components, including atomization devices that convert samples into gas-phase atoms and ions. There are two main types of atomization devices: continuous and discrete atomizers. Continuous atomizers, like plasmas and flames, introduce samples in a constant stream, while discrete atomizers inject individual samples using syringes or autosamplers. The most common discrete atomizer is the electrothermal atomizer.
346
Fluorescence and Phosphorescence: Instrumentation
556
Fluorometers and spectrofluorometers are two types of instruments used for measuring molecular fluorescence. These instruments differ in how they select excitation and emission wavelengths and the type of light sources they utilize. Fluorometers use absorption interference filters to choose excitation and emission wavelengths. The excitation source in a fluorometer is typically a low-pressure mercury vapor lamp that emits intense lines distributed throughout the ultraviolet and visible regions.
556
UV–Vis Spectrometers
1.3K
The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell.
1.3K