原子分辨率扫描传输电子显微镜在液温度下对量子材料进行扫描
Junsik Mun1, Daniel Potemkin2, Houk Jang3
1Condensed Matter Physics and Materials Science Department, Brookhaven National Laboratory, Upton, NY 11973, USA.
Ultramicroscopy
|September 14, 2024
概括
通过管理气流噪声,现在可以在低温电子显微镜中实现原子分辨率. 这一突破使得在液温度下对量子材料和设备的详细成像成为可能.
科学领域:
- 凝聚物质物理学 凝聚物质物理学
- 材料科学是一种材料科学.
- 电子显微镜的电子显微镜
背景情况:
- 凝聚物质中的量子现象需要较低的温度进行观测.
- 原子分辨率扫描传输电子显微镜 (cryo-STEM) 对于描述量子材料至关重要.
- 化STEM的挑战包括样本漂移和液冷却的噪音.
研究的目的:
- 为了证明原子分辨率的冷STEM成像在液温度下.
- 在冷STEM中识别和减轻噪声源.
- 应用先进的成像技术来研究量子材料中的结构相变.
主要方法:
- 使用商用侧入式液冷却容器用于STEM.
- 研究了STEM成像性能与气流速的比较.
- 开发了减少噪音的策略,包括抑制气体流动和在变暖过程中进行成像.
- 应用图像处理技术来分析结构相位过渡.
主要成果:
- 确定了气脉冲和泡作为主要噪音来源.
- 证明在加热过程中抑制气流或成像可以显著降低噪音.
- 成功地应用了这些方法来对Cr2Ge2Te6,CuIr2S4和CrCl3.3中的结构相变进行成像.
结论:
- 在液温度下进行原子分辨率的冷STEM成像,可以通过优化气体管理来实现.
- 开发的技术增强了量子材料和设备的特征.
- 这些发现提升了电子显微镜在低温量子材料研究方面的能力.
相关概念视频
Transmission Electron Microscopy
5.4K
In 1931, physicist Ernst Ruska—building on the idea that magnetic fields can direct an electron beam just as lenses can direct a beam of light in an optical microscope—developed the first prototype of the electron microscope. This development led to the development of the field of electron microscopy. In the transmission electron microscope (TEM), electrons are produced by a hot tungsten element and accelerated by a potential difference in an electron gun, which gives them up to 400...
5.4K
Overview of Electron Microscopy
8.6K
The wavelengths of visible light ultimately limit the maximum theoretical resolution of images created by light microscopes. Most light microscopes can only magnify 1000X, and a few can magnify up to 1500X. Electrons, like electromagnetic radiation, can behave like waves, but with wavelengths of 0.005 nm, they produce significantly greater resolution up to 0.05 nm as compared to 500 nm for visible light. An electron microscope (EM) can create a sharp image that is magnified up to 2,000,000X.
8.6K
Cryo-electron Microscopy
3.3K
Conventional electron microscopy (EM) involves dehydration, fixation, and staining of biological samples, which distorts the native state of biological molecules and results in several artifacts. Also, the high-energy electron beam damages the sample and makes it difficult to obtain high-resolution images. These issues can be addressed using cryo-EM, which uses frozen samples and gentler electron beams. The technique was developed by Jacques Dubochet, Joachim Frank, and Richard Henderson, for...
3.3K
Scanning Electron Microscopy
4.2K
A scanning electron microscope (SEM) is used to study the surface features of a sample by using an electron beam that scans the sample surface in a two-dimensional manner. Typically, areas between ~1 centimeter to 5 micrometers in width can be imaged. SEM can be used to image bacteria, viruses, tissues as well as larger samples like insects. Conventional SEM gives a magnification ranging from 20X to 30,000X and spatial resolution of 50 to 100 nanometers.
Fundamental Principles
Accelerated...
Fundamental Principles
Accelerated...
4.2K
Electron Microscope Tomography and Single-particle Reconstruction
2.4K
Transmission electron microscopy (TEM) can be used to determine the 3D structure of biological samples with the help of techniques such as electron microscope tomography and single-particle reconstruction. While single-particle reconstruction can examine macromolecules and macromolecular complexes in vitro conditions only, tomography permits the study of cell components or small cells in vivo.
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
2.4K
Preparation of Samples for Electron Microscopy
5.4K
To be visualized by an electron microscope, either transmission or scanning, biological samples need to be fixed (stabilized) so the electron beam does not destroy them and dried thoroughly (desiccated/dehydrated) so the vacuum does not affect them. Fixation needs to be done as quickly as possible because the sample properties will start changing as soon as it is removed from its natural environment. For example, in a tissue sample, the oxygen levels begin decreasing, causing an altered...
5.4K