在住院高血压患者中,无人监护和常规血压测量
1Department of Hypertension, Ruijin Hospital, Shanghai Jiaotong University School of Medicine.
Blood pressure monitoring
|September 16, 2024
概括
无人监护血压监测与住院高血压患者的传统方法一样准确. 这种方法可以安全地用于临床环境中的常规血压管理.
科学领域:
- 心脏病学 心脏病学
- 高血压管理 高血压管理
- 临床测量 临床测量
背景情况:
- 高血压是住院患者中普遍存在的疾病.
- 精确的血压测量对于有效的管理至关重要.
- 目前的标准涉及护士监控的 (传统) 测量.
研究的目的:
- 为了比较无人监督血压测量与传统方法的准确性和可靠性.
- 评估住院高血压患者无人监护血压监测的可行性.
主要方法:
- 一项涉及92名住院高血压患者的比较研究.
- 使用电子血压监测器进行无人监督和常规测量.
- 采用统计分析,包括类内相关系数和布兰德-阿尔特曼图.
主要成果:
- 在无人监督和传统方法之间没有发现血压读数的显著差异.
- 观察到微小的变化 (1-2 mmHg),在常规测量轮期间,静脉血压有统计显著下降.
- 亚组分析 (年龄,性别,BMI,糖尿病) 证实了不同患者人口统计学方面的一致性.
结论:
- 在住院高血压患者中,无人监督的血压测量显示了与传统方法相比的准确性.
- 无人监控监测是常规血压管理的可行和潜在的优越替代方案.
- 支持将无人监督血压测量作为标准临床实践的采用.
更多相关视频
07:35Simultaneous Electrocardiography Recording and Invasive Blood Pressure Measurement in Rats
Published on: January 31, 2019
15.2K
09:38Femoral Arterial and Venous Catheterization for Blood Sampling, Drug Administration and Conscious Blood Pressure and Heart Rate Measurements
Published on: January 24, 2012
124.7K
相关概念视频
Special considerations while measuring blood pressure
710
When assessing blood pressure (BP), healthcare professionals must consider various factors and potential unexpected outcomes to ensure accurate readings and provide proper patient care. Adhering to these guidelines is essential to achieving the most reliable results.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
710
Equipments Used To Measure Blood Pressure
846
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
846
Measurement of Blood Pressure
896
Assessing blood pressure is a standard procedure executed in virtually all medical environments. The method utilized today was established over a hundred years ago by an innovative Russian doctor, Dr. Nikolai Korotkoff. The soft ticking noise, known as Korotkoff sounds, heard while taking blood pressure readings results from turbulent blood flow within the vessels. The apparatus required for this procedure includes a sphygmomanometer, a blood pressure cuff attached to a gauge, and a...
896
Assessment of blood pressure in brachial artery(two-step method)
661
Measuring blood pressure is a fundamental skill in healthcare that aids in diagnosing and monitoring hypertension and other cardiovascular conditions. An aneroid sphygmomanometer, commonly used in clinical settings, offers a manual and precise method for blood pressure measurement. The technique for using this instrument involves specific steps that must be carefully executed to ensure accuracy. The following detailed description outlines a two-step technique for assessing blood pressure using...
661
Sites for measruring blood pressure
1.5K
Blood pressure measurement is a fundamental clinical procedure, providing crucial data for assessing cardiovascular health. Among the various sites for this measurement, the brachial and popliteal arteries are predominantly utilized due to their accessibility and the reliability of their readings. This lesson delves into the anatomical significance, methodology, and considerations of measuring blood pressure at these locations.
The Brachial Artery: Primary Site for Blood Pressure Measurement
The Brachial Artery: Primary Site for Blood Pressure Measurement
1.5K
Pre-Procedural Guidelines for Assessing Blood Pressure
525
Accurate blood pressure assessment is crucial for diagnosing and managing various health conditions. To ensure the reliability of these measurements, healthcare professionals must adhere to standardized pre-procedural guidelines. These guidelines enhance patient safety and improve the overall quality of healthcare. The following steps are essential for obtaining accurate and consistent blood pressure readings, from using the appropriate tools to ensuring effective communication with the...
525