相关实验视频
Updated: Jun 12, 2025

11:21
Cooling an Optically Trapped Ultracold Fermi Gas by Periodical Driving
Published on: March 30, 2017
7.4K
库频段300千瓦的高功率费里特相位变速器
Xianggang Hu1,2, Jiancang Su2, Bing Bai3
1College of Advanced Interdisciplinary, National University of Defense Technology, Changsha 410073, China.
The Review of scientific instruments
|September 17, 2024
概括
本研究介绍了一种新型的双 toroid 费里特相位变换器 (FPS) 用于高功率微波 (HPM) 阶段阵列天线 (PAA) 系统. 增强的FPS在Ku频段实现了超过300kW的功率处理,克服了传统设备的局限性.
科学领域:
- 微波工程 微波工程
- 材料科学 材料科学 材料科学
- 天线系统天线系统
背景情况:
- 费里特相位变换器 (FPS) 对相位阵列天线 (PAA) 至关重要,提供快速切换,低损耗和高可靠性.
- 传统的Ku频段FPS具有有限的功率处理 (kW范围),限制它们在高功率微波 (HPM) PAA系统中的使用.
研究的目的:
- 为HPM PAA应用开发一种具有外部磁激发的新型双 toroid FPS.
- 为了显著提高FPS的功率处理能力,同时保持性能.
主要方法:
- 设计了一个新的双 toroid FPS 结构与外部磁激发.
- 优化了相变器配置和集成过程.
- 提高了FPS中使用的费里特材料的性能.
主要成果:
- 在单个Ku频段FPS中实现了超过300kW的功率处理能力.
- 保持低插入损失 (<-1.2dB) 和完整的0°-360°相位转移范围.
- 将设备宽度缩小到 < 11.5 mm,并证明适用于一维数组.
结论:
- 开发的双 toroid FPS 克服了传统铁相位变速器的功率限制.
- 这一进步使FPS能够在HPM PAA系统中使用,为未来的研发铺平了道路.
相关概念视频
Power Factor Correction
159
The power transmission to a factory involves the transfer of apparent power, a combination of active and reactive power. The power factor measures how effectively electrical power is converted into useful work output. The ratio of the real power (KW) that does the work to the apparent power (KVA) supplied to the circuit.
159
Reducing Line Loss
149
In a three-phase circuit, line loss is an indicator of energy dissipated as heat due to the resistance of transmission lines. To address this, incorporating transformers into the system—a step-up transformer at the source and a step-down transformer at the load—is a strategic solution. Two three-phase transformers are introduced to improve this.
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...
149
Three-Phase Voltages
219
A three-phase generator produces three voltages that are equal in magnitude but have a phase difference of 120 degrees. This identical magnitude and equal phase separated voltages are known as the balanced voltages and help to minimize power loss while ensuring a steady delivery of energy to connected loads. As voltage sources in a three-phase system can be configured in a wye or a delta formation, the loads connected to these systems can also be arranged in either configuration. This...
219
Generation of Three-Phase Voltage
363
A three-phase AC generator has a rotor with a rotating magnet placed within the stator mounted with the stationary three-phase winding to generate three-phase voltages via mutual induction. These windings are evenly distributed around the inner circumference of the stator and are arranged 120 electrical degrees apart. Three-phase stator windings consist of three separate coils or groups of coils, known as phases, each connected in Y (star) configuration or Delta configuration.
As the rotor...
As the rotor...
363
Three-Winding Transformers
215
Three identical single-phase transformers can be configured to form a three-phase transformer connection, which involves high-voltage and low-voltage windings. The high-voltage windings are denoted by capital letters A-B-C, while the low-voltage windings are labeled with lowercase letters a-b-c, representing their respective phases. This notation helps distinguish between the high and low voltage sides of the transformer.
In the per-unit equivalent circuit of a grounded Y-Y three-phase...
In the per-unit equivalent circuit of a grounded Y-Y three-phase...
215
Instrument Transformers
76
Instrument transformers, comprising voltage transformers (VTs) and current transformers (CTs), play crucial roles in power substations by providing isolated replicas of current or voltage for measurement and protection purposes. Voltage transformers reduce the primary voltage to levels suitable for relay operation and measurement, while current transformers scale down the primary current. The primary winding of a current transformer often consists of a single turn, achieved by threading the...
76