在多孔气体扩散电极内的二碳酸盐和pH的近电极度梯度,用于优化选择性CO2电降解到C2+的产品

Yao Tan1, Xiqing Wang1, Xiangqiong Liao1

  • 1Hunan Joint International Research Center for Carbon Dioxide Resource Utilization, School of Physics, Central South University, Changsha 410083, People's Republic of China.

Nano letters
|September 18, 2024
PubMed
概括

在气体扩散电极 (GDE) 中优化多孔催化剂层 (CL) 可增强二氧化碳减排反应 (CO2RR). 较高孔径的CLs缓冲性,并提高对有价值的C2+产品的CO2RR选择性.

相关概念视频

Potentiometry: Membrane Electrodes01:15

Potentiometry: Membrane Electrodes

Membrane electrodes, also known as p-ion electrodes, use membranes that selectively interact with free analyte ions, generating a potential difference across the membrane. The resulting membrane potential, known as the asymmetry potential, is not zero even when analyte concentrations on both sides of the membrane are equal. The membrane's response is typically not selective to a single analyte but proportional to the concentration of all ions in the sample solution capable of interacting at...
488
Concentration Cells02:41

Concentration Cells

A concentration cell is a type of a  voltaic cell constructed by connecting two almost identical half-cells, both based on the same half-reaction and using the same electrode, differing only in the concentration of one redox species. A concentration cell's potential, therefore, is determined only by the concentration difference of the particular redox species.
Consider the following voltaic cell:
22.4K
Controlled-Potential Coulometry: Electrolytic Methods01:17

Controlled-Potential Coulometry: Electrolytic Methods

Controlled-potential coulometry, also known as potentiostatic coulometry, employs a three-electrode system in which the working electrode's potential is precisely regulated using a potentiostat. Platinum working electrodes are utilized for positive potentials, while mercury pool electrodes are favored for extremely negative potentials. The platinum counter electrode is separated from the analyte using a membrane or salt bridge to avoid interference in the analysis.
The chosen potential...
148
Polyprotic Acids03:38

Polyprotic Acids

Acids are classified by the number of protons per molecule that they can give up in a reaction. Acids such as HCl, HNO3, and HCN that contain one ionizable hydrogen atom in each molecule are called monoprotic acids. Their reactions with water are:
29.1K
Bicarbonate-Carbonic Acid Buffer01:22

Bicarbonate-Carbonic Acid Buffer

The carbonic acid-bicarbonate buffer system is critical for maintaining the body's pH balance. It operates on the equilibrium:
913
Controlled-Current Coulometry: Overview01:27

Controlled-Current Coulometry: Overview

Controlled current coulometry, also known as amperostatic coulometry, is a technique used in electrochemical analysis to measure the quantity of a substance through the controlled passage of current. It involves the application of a constant current to an electrochemical cell containing the analyte of interest. As the current flows through the cell, the analyte undergoes a redox reaction at the electrode surface, resulting in a charge transfer. By monitoring the time required for a certain...
172