为居民解决饮用水中的铜问题提供指导:机遇和挑战
Rebecca Kriss1, Marc A Edwards1
1Civil and Environmental Engineering, Virginia Tech, 418 Durham Hall, Blacksburg, Virginia 24061, United States.
概括
饮用水中的高铜含量对健康构成风险. 这项研究提供了关于检测和处理高铜水平的指导,特别是对于那些私人井不完全受到法规覆盖的人来说.
科学领域:
- 环境科学 环境科学
- 公共卫生 公共卫生
- 水的质量 水的质量
背景情况:
- 饮用水中铜含量升高可能会对居民和物造成健康和美学问题.
- 美国环保署的和铜规则有局限性,使一些消费者容易受到高铜含量的影响 (铜溶性).
- 居民需要指导,以了解,检测和解决水中的铜溶性.
研究的目的:
- 为居民制定管理饮用水的指导方针.
- 为了确定准确的铜和pH的在家测试方法.
- 为减少铜水平的干预策略提供信息.
主要方法:
- 评估了家庭测试工具包对铜和pH的准确性.
- 对水处理效率进行了案例研究.
- 为居民和公民科学家开发了一个决策树.
主要成果:
- 三个铜和一个pH在家用测试套件显示出足够的准确性来检测铜溶解性问题.
- 在现场调整pH值可能是有效的,但可能需要长期治疗 (超过36周).
- 创建了一个决策树,以协助管理公共和私人水务系统的铜融资.
结论:
- 居民可以有效地监测和解决饮用水的铜溶性,使用验证的家用测试套件.
- 经常需要长期的水处理策略来持续降低铜含量.
- 开发的指导和决策树使个人能够管理水质问题.
相关概念视频
Precipitation and Co-precipitation
1.7K
Precipitation and coprecipitation methods can be used to separate a mixture of ions in a solution. In qualitative inorganic analysis, ions that form sparingly soluble precipitates with the same reagent are separated based on the differences in solubility products. For example, consider the separation of Cu(II) and Fe(II) ions by precipitation as insoluble sulfides. First, copper(II) sulfide is precipitated by the addition of acidic H2S, where the dissociation of H2S is suppressed. Adding H2S...
1.7K
Electrodeposition
611
Electrodeposition is a technique used to separate an analyte from interferents by electrochemical processes. Here, the analyte is a metal ion that can be deposited on an electrode immersed in the sample solution. The electrochemical setup consists of an anode and a cathode. When an electric current is applied to the setup, oxidation occurs at the anode. At the cathode, which consists of a large metal surface, metal ions undergo reduction and deposit onto the surface.
Electrodeposition can...
Electrodeposition can...
611
Extraction: Advanced Methods
432
Metal ions can be separated from one another by complexation with organic ligands–the chelating agent– to form uncharged chelates. Here, the chelating agent must contain hydrophobic groups and behave as a weak acid, losing a proton to bind with the metal. Since most organic ligands used in this process are insoluble or undergo oxidation in the aqueous phase, the chelating agent is initially added to the organic phase and extracted into the aqueous phase. The metal-ligand complex is...
432
Corrosion
23.9K
The degradation of metals due to natural electrochemical processes is known as corrosion. Rust formation on iron, tarnishing of silver, and the blue-green patina that develops on copper are examples of corrosion. Corrosion involves the oxidation of metals. Sometimes it is protective, such as the oxidation of copper or aluminum, wherein a protective layer of metal oxide or its derivatives forms on the surface, protecting the underlying metal from further oxidation. In other cases, corrosion is...
23.9K
Controlled-Current Coulometry: Overview
172
Controlled current coulometry, also known as amperostatic coulometry, is a technique used in electrochemical analysis to measure the quantity of a substance through the controlled passage of current. It involves the application of a constant current to an electrochemical cell containing the analyte of interest. As the current flows through the cell, the analyte undergoes a redox reaction at the electrode surface, resulting in a charge transfer. By monitoring the time required for a certain...
172
Effects of EDTA on End-Point Detection Methods
264
Different methods, such as visual observance of metal-ion indicators, spectroscopic techniques, and potentiometric methods, can determine the endpoint of an EDTA titration.
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
264


