在便样本中对样本度进行色度校正
Joris R Delanghe1, Jan Van Elslande1, Maaike J Godefroid1
1Labo Maenhout, Waregem, Belgium.
Clinical chemistry and laboratory medicine
|September 20, 2024
概括
使用stercobilin对便免疫化学测试 (FIT) 和便calprotectin结果进行校正,可以改善解释. 这种方法可以解释便样本的稀释,从而更准确地检测结直肠癌和肠道炎症.
科学领域:
- 临床化学 临床化学
- 胃肠病学 胃肠病学
- 生物化学 生物化学
背景情况:
- 便免疫化学测试 (FIT) 和便calprotectin是分别用于结直肠癌查和肠道炎症监测的标准.
- 分析前的问题,特别是可变的便含水量,挑战了这些测试的准确性.
- 目前,没有参考分析物存在,以标准化基于样本水分的结果.
研究的目的:
- 作为参考分析物,用于纠正便样本的分析前变异,对斯特科比林进行研究.
- 评估基于斯特科比林的校正对FIT和便calprotectin结果的解释的影响.
主要方法:
- 稳定的血代谢物斯特科比林在便提取物中使用色度计 (I指数) 进行了测试.
- 使用Atellica平台测量血清指数 (H,I,L) 和胆红素度.
- 中位数I指数被用来纠正便样本稀释.
主要成果:
- 斯特科比林度显示出高个体间的差异,允许对样本稀释进行校正.
- 纠正FIT结果增加了阳性测试,从9.3%增加到11.7%.
- 便calprotectin校正产生了3.1%更多的积极结果和7.7%更多的负面结果.
结论:
- 基于斯特科比林的校正适用于FIT和便calprotectin,除了阻塞性黄.
- 为样本稀释调整结果可以提高对常见便分析物的解释.
- 这种方法可能会导致对结直肠癌和炎症性肠病的临床决策更加精确.
相关概念视频
Fixation and Sectioning
Two basic types of preparation are used to visualize specimens with a light microscope: wet mounts and fixed specimens.
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
Testing a Claim about Standard Deviation
A complete procedure to test a claim about population standard deviation or population variance is explained here.
The hypothesis testing for the claim of population standard deviation (or variance) requires the data and samples to be random and unbiased. The population distribution also must be normal. There is no specific requirement on the sample size as the estimation is based on the chi-square distribution.
As a first step, the hypothesis (null and alternative) concerning the claim about...
The hypothesis testing for the claim of population standard deviation (or variance) requires the data and samples to be random and unbiased. The population distribution also must be normal. There is no specific requirement on the sample size as the estimation is based on the chi-square distribution.
As a first step, the hypothesis (null and alternative) concerning the claim about...
Systematic Error: Methodological and Sampling Errors
In the case of systematic errors, the sources can be identified, and the errors can be subsequently minimized by addressing these sources. According to the source, systematic errors can be divided into sampling, instrumental, methodological, and personal errors.
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Instrument Calibration
Instrument calibration is essential for ensuring that instruments produce accurate and consistent results. It is vital in manufacturing, healthcare, testing laboratories, and scientific research. Calibration processes are specific to each instrument and help enhance data accuracy. Each instrument has a unique calibration process tailored to its design and function to improve data accuracy.
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Contaminants and Errors
Effective sample preparation is crucial for accurate and reliable laboratory analysis. During this process, two significant sources of error can arise: concentration bias from improper sample splitting and contamination caused by methods used to reduce particle size, such as grinding or homogenization. Identifying and minimizing these potential errors is crucial to ensuring the validity of the analysis.
Another key consideration is determining the appropriate number of samples required to...
Another key consideration is determining the appropriate number of samples required to...
Distance Corrections
To achieve precise distance measurements, especially in surveying and construction, certain corrections must be applied to account for potential sources of error like the standardization errors, temperature variations, and slope adjustments.Standardization error emerges when measurement equipment undergoes changes, such as wear, repairs, or weather impacts. To address this, surveyors compare the equipment’s readings to a standard. This process identifies any deviation that might lead to...