在基于ANN的核心和条件下恢复电流变压器的二次电流
Ismoil Odinaev1, Abdel-Haleem Abdel-Aty2, Andrey Pazderin1
1Department of Automated Electrical Systems, Ural Federal University, 620002, Yekaterinburg, Russia.
Heliyon
|September 26, 2024
概括
电流变压器核心和会扭曲电信号,影响电力系统的保护. 一种新的人工神经网络方法有效地恢复扭曲的电流信号,将继电器保护的准确性提高了1.25倍.
科学领域:
- 电气工程 电气工程
- 电力系统 电力系统
- 人工智能的人工智能
背景情况:
- 继电保护和应急自动化对于电力系统至关重要.
- 算法依赖于仪表变压器的电流和电压数据.
- 在故障条件下,当前变压器核心和会扭曲信号,导致错误操作.
研究的目的:
- 解决电流变压器核心和问题及其对继电器保护的影响.
- 提出和评估一种用于恢复扭曲电流信号的新方法.
主要方法:
- 对处理电流变压器和现有方法的比较分析.
- 制定和问题作为回归任务.
- 开发和应用基于人工神经网络 (ANN) 的方法.
- 实施实时数据再缩放技术用于信号恢复.
主要成果:
- 与现有技术相比,拟议的基于ANN的方法显示出更高的性能.
- 发现,拟议方法的效率是现有最有效方法的1.25倍.
- 通过计算实验的验证证实了拟议方法的有效性.
结论:
- 人工神经网络为减轻当前变压器核心和效应提供了一个有希望的解决方案.
- 开发的方法提高了继电器保护和应急自动化系统的可靠性.
- 实时数据再缩放是一种可行的技术,可以恢复扭曲的电流波形.
相关概念视频
Equivalent Circuits for Practical Transformers
400
The practical equivalent circuits of single-phase two-winding transformers exhibit significant deviations from their idealized versions due to the inherent properties of winding resistance and finite core permeability. These properties result in real and reactive power losses, affecting the transformer's performance. Understanding these deviations is crucial for designing more efficient transformers.
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
400
Instrument Transformers
76
Instrument transformers, comprising voltage transformers (VTs) and current transformers (CTs), play crucial roles in power substations by providing isolated replicas of current or voltage for measurement and protection purposes. Voltage transformers reduce the primary voltage to levels suitable for relay operation and measurement, while current transformers scale down the primary current. The primary winding of a current transformer often consists of a single turn, achieved by threading the...
76
Three-Phase Short Circuit—Unloaded Synchronous Machine
128
Conducting a three-phase short circuit test on an unloaded synchronous machine helps understand its impact on the system. The AC fault current's oscillogram, with the DC offset removed, reveals that the waveform amplitude decreases from an initially high value to a steady-state level for one phase of the machine.
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
128
Power System Three-Phase Short Circuits
78
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
78
Energy Losses in Transformers
843
In an ideal transformer, it is assumed that there are no energy losses, and, hence, all the power at the primary winding is transferred to the secondary winding. However, in reality, the transformers always have some energy losses, and, hence, the output power obtained at the secondary winding is less than the input power at the primary winding due to energy losses.
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
843
Overcurrent Relays
73
Overcurrent relays, crucial for circuit protection, are connected to the secondary current of a current transformer. There are two primary types of overcurrent relays: instantaneous and time-delay.
Instantaneous overcurrent relays activate immediately when the input current exceeds a predetermined value, known as the pickup current, instantly energizing the circuit breaker trip coil. This rapid response is vital for addressing severe faults quickly.
Time-delay overcurrent relays, on the other...
Instantaneous overcurrent relays activate immediately when the input current exceeds a predetermined value, known as the pickup current, instantly energizing the circuit breaker trip coil. This rapid response is vital for addressing severe faults quickly.
Time-delay overcurrent relays, on the other...
73