快速烧结过程对石微观结构,屈曲强度和半透明度的影响
Mayada Hadi Abed1, Alaa Jawad Kadhim1
1Conservative and esthetic dentistry department, College of dentistry/ University of Baghdad, Iraq.
Heliyon
|September 26, 2024
概括
与传统方法相比,的快速烧结 (Y-TZP) 对微观结构,屈曲强度或半透明度没有显著影响. 这种更快的工艺适用于化制造,提供了轻微的改进.
科学领域:
- 材料科学 材料科学 材料科学
- 生物材料工程 生物材料工程
- 陶工程 陶工程
背景情况:
- 陶由于其优良的机械性能,在牙科中被广泛使用.
- 传统的烧结需要延长加工时间,影响实验室效率.
- 探索更快的烧结方法,如速度烧结,对于优化牙科材料加工至关重要.
研究的目的:
- 为了评估速度烧结与常规烧结对的微观结构,屈曲强度和半透明度的影响.
- 为了比较不同商业合金配方的快速烧结结果.
主要方法:
- 通过使用常规和速度程序准备和烧结了四种商业陶.
- 分析X射线衍射 (XRD) 分析的相组合.
- 扫描电子显微镜 (SEM) 评估了颗粒大小.
- 屈曲强度根据ISO 6872:2015进行测量.
- 透光度是使用光谱光度计进行评估的.
主要成果:
- 在烧结方法 (XRD) 之间没有观察到显著的相变.
- 在所有组 (SEM) 中,平均颗粒大小保持在1μm以下.
- 与传统烧结相比,速度烧结显示出与常规烧结相比,增大颗粒大小,屈曲强度和半透明度的非显著趋势 (P > 0.05).
结论:
- 快速烧结不会显著改变经过测试的石材料的微观结构,屈曲强度或半透明度.
- 快速烧结为氧化加工提供了一种节省时间的替代方案,具有轻微性能改善的潜力.
- 速度烧结程序被认为适用于 (Y-TZP) 制造.
相关概念视频
Stress-Strain Diagram - Brittle Materials
4.6K
Brittle materials, including glass, cast iron, and stone, exhibit unique characteristics. They fracture without considerable change in their elongation rate, indicating that their breaking and ultimate strength are equivalent. Such materials also show lower strain levels at the point of rupture. The failure in brittle materials predominantly results from normal stresses, as evidenced by the rupture created along a surface perpendicular to the applied load. These materials do not display...
4.6K
Deleterious Substances in Aggregate
867
Deleterious substances in aggregates can be detrimental to the quality and durability of concrete. These substances include organic impurities like loam, which interfere with cement hydration and are usually present in the sand. These prevent a good bond between aggregate and cement paste. Organic impurities can be detected using the colorimetric test, where the darkness of a solution after agitation indicates the level of organic content.
Another type of impurity is clay and fine material that...
Another type of impurity is clay and fine material that...
867
Pore Size Distribution
691
In concrete, the pore size distribution significantly influences the material's properties. Capillary pores, markedly larger than gel pores, form a vast network within partially hydrated cement paste, reducing the concrete's strength and increasing its permeability. This heightened permeability leads to a greater risk of damage from environmental factors like freeze-thaw cycles and chemical attacks, with the extent of vulnerability also being tied to the water-to-cement ratio.
Adequate...
Adequate...
691
Microcracking in Concrete
621
Microcracking in concrete refers to the tiny cracks that can form within the material even before any external load is applied. These microcracks typically occur at the interface between the coarse aggregate and the hydrated cement paste, often as a result of differential volume changes prompted by variations in stress-strain behavior, as well as thermal and moisture movement. Initially, these microcracks remain stable and do not grow substantially until the concrete is stressed to about 30...
621
Transition Zone
546
The transition zone in concrete is a critical area where aggregate meets cement paste, marked by a distinct porosity and weakness compared to the surrounding material. The adhesion around the aggregates is primarily due to Van Der Waals forces. The voids within this zone influence its robustness; initially, it is less durable than the surrounding bulk mortar due to larger voids. Initially, when concrete is compacted, a higher water-cement ratio near the aggregates leads to the formation of...
546
Drying Shrinkage
530
When hardened concrete is exposed to air with a relative humidity of less than 100 percent, it begins to lose the free water within its capillaries. As this water evaporates, the water initially adsorbed onto the calcium silicate hydrates migrates towards these now empty spaces and eventually evaporates as well. Over time, as more water leaves, the volume of the concrete decreases, a phenomenon known as drying shrinkage.
A portion of this drying shrinkage can be reversed; if the concrete is...
A portion of this drying shrinkage can be reversed; if the concrete is...
530