一个单个分子的光检测二维电子光谱
Sanchayeeta Jana1, Simon Durst1, Markus Lippitz1
1Experimental Physics III, University of Bayreuth, 95447 Bayreuth, Germany.
Nano letters
|September 27, 2024
概括
我们开发了一种结合单分子光谱和二维光谱的新技术,以在室温下研究单个二二烯 (DBT) 分子的超快动态. 这种方法为单个量子系统中的能量转移提供了新的见解.
科学领域:
- 物理化学 物理化学
- 频谱学是一种光谱学.
- 量子光学是一种量子光学.
背景情况:
- 单分子光谱学提供高灵敏度,但仅限于纳秒时间分辨率.
- 组合平均二维光谱显示了超快的动态 (femtoseconds),但缺乏单个分子的特异性.
- 将这些技术结合起来,对于理解单量子级超快速过程至关重要.
研究的目的:
- 将单分子检测与连贯的二维光谱学相结合.
- 为了实现单个量子发射器的femtosecond时间分辨率.
- 为了研究单个二二二烯 (DBT) 分子中的超快能量转移动力学.
主要方法:
- 使用共聚焦显微镜设置进行单分子激发,使用相调节的秒脉冲列车.
- 用于光检测的单光子计数探测器.
- 实施了相位敏感检测方案来测量非线性2D光谱.
主要成果:
- 成功地在室温下对单个二二二烯 (DBT) 分子进行了连贯的二维光谱.
- 测量了大量研究的DBT分子的非线性2D光谱.
- 为单个量子发射器实现了高时间分辨率.
结论:
- 开发的方法成功地将单分子灵敏度与超快的时间分辨率相结合.
- 这种技术为研究单个量子物体中的能量转移和其他超快现象开辟了新的途径.
- 适用于基础研究的广泛的单一排放者.
相关概念视频
Two-Dimensional (2D) NMR: Overview
631
The 1D NMR spectrum of large and complex molecules like natural products has complicated splitting patterns and overlapping signals, which can be easily interpreted using 2-dimensional (2D) NMR. Unlike 1D NMR, 2D NMR has two frequency axes that provide the coupling information between the nucleus A and nucleus B in a molecule. The process from which 2D spectra are obtained has four steps.
The first step is the preparation period, during which nucleus A is excited with a radiofrequency pulse....
The first step is the preparation period, during which nucleus A is excited with a radiofrequency pulse....
631
Atomic Spectroscopy: Absorption, Emission, and Fluorescence
820
Atomic spectroscopy is a vital tool in elemental analysis, both qualitatively and quantitatively. It can be broadly divided into optical spectroscopy, mass spectroscopy, and X-ray spectroscopy methods. The optical spectroscopic methods are atomic absorption spectroscopy (AAS), atomic emission spectroscopy (AES), and atomic fluorescence spectroscopy (AFS). The first step in all three methods is atomization, where the solid, liquid, or solution-phase samples are converted into gas-phase atoms and...
820
Super-resolution Fluorescence Microscopy
6.9K
Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been...
6.9K
Molecular Spectroscopy: Absorption and Emission
1.9K
Molecules possess discrete energy levels called quantum states. Unlike atoms, which have simpler energy levels, molecules possess additional rotational and vibrational energy levels. Each energy level is separated by an energy gap, with the gaps between adjacent electronic, vibrational, and rotational levels varying significantly. The three types of energy levels in a diatomic molecule are shown in Figure 1.
1.9K
Protein Dynamics in Living Cells
2.1K
Different fluorescence-based techniques are used to study the protein dynamics in living cells. These techniques include FRAP, FRET, and PET.
Fluorescent recovery after photobleaching (FRAP) is a fluorescent-protein-based detection technique used to quantify protein movement rates within the cell. This method exposes a small portion of the cell to an intense laser beam. The laser beam causes permanent photobleaching of the fluorophore-tagged proteins in the exposed region. As the bleached...
Fluorescent recovery after photobleaching (FRAP) is a fluorescent-protein-based detection technique used to quantify protein movement rates within the cell. This method exposes a small portion of the cell to an intense laser beam. The laser beam causes permanent photobleaching of the fluorophore-tagged proteins in the exposed region. As the bleached...
2.1K
Fluorescence and Phosphorescence: Instrumentation
555
Fluorometers and spectrofluorometers are two types of instruments used for measuring molecular fluorescence. These instruments differ in how they select excitation and emission wavelengths and the type of light sources they utilize. Fluorometers use absorption interference filters to choose excitation and emission wavelengths. The excitation source in a fluorometer is typically a low-pressure mercury vapor lamp that emits intense lines distributed throughout the ultraviolet and visible regions.
555


