概括
本研究介绍了微电网中的数据分发服务 (DDS) 协议的基于角色的访问控制 (RBAC) 安全方法. 这提高了电力系统中物联网 (IoT) 设备的网络安全和网络弹性.
科学领域:
- 电气工程 电气工程
- 计算机科学 计算机科学
- 网络安全 网络安全
背景情况:
- 传统的电网由于单向的能量流而遭受效率低下.
- 微电网通过双向流量和独立的电源提供更高的效率.
- 微电网中的物联网 (IoT) 协议引入了重要的网络安全漏洞.
研究的目的:
- 解决微电网通信系统中的安全漏洞.
- 提高微电网运营的网络弹性.
- 为支持物联网的微电网提出一种新的安全方法.
主要方法:
- 实现基于角色的访问控制 (RBAC) 安全模型.
- 将RBAC与数据分发服务 (DDS) 协议集成.
- 使用可扩展访问控制标记语言 (XACML) 来执行政策.
- 角色分配和许可授予微电网内的用户和设备.
主要成果:
- 减少物联网设备之间的通信中的安全漏洞.
- 加强对入侵威胁的网络弹性.
- 展示了政策决策和执行的功能性实施模型.
结论:
- 提出的基于RBAC的安全方法有效地减轻了微电网通信中的风险.
- 这种方法加强了微电网系统的整体网络安全态度.
- 该方法有助于未来电网的稳定和高效运行.
相关概念视频
SBAR I: Understanding the Concept
4.4K
Effective communication among healthcare professionals during hand-off reporting is essential to delivering safe and continuous patient care. Common professional interactions include reports to healthcare team members, hand-off, and transfer reports. Nurses routinely report information to other healthcare team members and also urgently contact healthcare providers to report changes in patient status.
Standardized methods of communication have been developed to ensure that information is...
Standardized methods of communication have been developed to ensure that information is...
4.4K
Radial System Protection
92
Radial systems employ time-delay overcurrent relays to reduce load interruptions. When a fault occurs, the nearest breaker opens first, while upstream breakers remain closed due to longer delay settings. This approach ensures minimal disruption to the rest of the system.
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
92
Comparison between RL and RC circuits
3.9K
An RC circuit consists of resistance and capacitance, while in an RL circuit, capacitance is replaced by an inductor. RL and RC circuits are first-order differential circuits that store energy. An RC circuit stores energy in the electric field, while an RL circuit stores energy in the magnetic field. When connected to a battery, an RC circuit charges the capacitor, causing the current to decrease from maximum to zero upon being fully charged. This increases the voltage across the capacitor from...
3.9K
Applications of RC Circuits
3.0K
A relaxation oscillator is one of the applications of RC circuits. A neon lamp relaxation oscillator comprises a capacitor, a resistor, a voltage source, and a lamp. The lamp acts like an open circuit, with infinite resistance until the potential difference across the lamp reaches a specific voltage. At that voltage, the lamp acts like a short circuit with zero resistance, and the capacitor discharges through the lamp, thus producing light. Once the capacitor is fully discharged through the...
3.0K
Line Protection with Impedance Relays
69
Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
Under normal conditions, low load currents keep the measured...
69
Issues And Trends In Healthcare Delivery System
5.6K
The issues and trends in healthcare delivery are constantly changing. The COVID-19 pandemic is one recent issue that wreaked havoc on healthcare systems, causing a shortage of healthcare workers, high demand for medicines and supplies, and increased medical expenditure due to a lack of insurance. Other issues include rising healthcare costs and care fragmentation.
Cost Containment
Payment for healthcare services has historically promoted adoption of costly and often unnecessary or inefficient...
Cost Containment
Payment for healthcare services has historically promoted adoption of costly and often unnecessary or inefficient...
5.6K