一个具有自主移动机器人主动地标的自适应和自动电源分配系统
Zhen Li1, Yuliang Gao2, Miaomiao Zhu3
1School of Electrical Engineering and Automation, Nantong University, Nantong 226021, China.
Sensors (Basel, Switzerland)
|September 28, 2024
概括
本研究介绍了自主移动机器人的活跃发光地标,克服了路线不灵活性. 自动电源系统可以提高机器人的运行时间和系统效率.
科学领域:
- 机器人技术 机器人技术 机器人技术
- 自动化系统 自动化系统
背景情况:
- 工业自动化需要移动机器人来完成劳动密集型任务和短缺.
- 传统的机器人使用被动标记,导致不灵活性和高成本.
- 电池驱动的活跃地标提供灵活的导航,但需要经常充电.
研究的目的:
- 为活跃的地标开发一个自动电源系统.
- 为了应对电极大小和非适应性充电的挑战.
- 通过使用主动地标来提高移动机器人的实用性和效率.
主要方法:
- 提出了一种新的方法,使用电池驱动的发光活性地标.
- 开发了一种自动电源系统,配有全向接触电极.
- 专注于缩小地标和优化电力分配.
主要成果:
- 自动电源方法的有效性和地标检测准确性的证明.
- 通过自适应能量分配,实现了系统持久性的近三倍改进.
- 成功缩小了活跃的地标和优化了电力分配.
结论:
- 拟议的系统提高了移动机器人的实用性和效率.
- 适应式发电系统可显著延长运行时间.
- 简化安装和自动充电改善了工业机器人应用.
相关概念视频
Distribution Reliability and Automation
107
Distribution reliability in electrical power systems is critical for ensuring an uninterrupted power supply to consumers at minimal cost. According to IEEE Standard Terms, reliability is the probability that a device will function without failure over a specified time period or amount of usage. For electric power distribution, this translates to maintaining continuous power supply and addressing customer concerns over power outages. Several indices, as defined by IEEE Standard 1366-2012, are...
107
Reclosers and Fuses
89
Automatic circuit reclosers enhance the protection of distribution circuits by interrupting and auto-reclosing an AC circuit according to a preset sequence. They effectively manage temporary faults on overhead distribution lines, often caused by tree limbs or wildlife, by briefly disrupting service to improve overall reliability. However, contact with reclosers or energized broken conductors on the ground can pose serious hazards.
A comprehensive protection scheme for radial distribution...
A comprehensive protection scheme for radial distribution...
89
Transformers in Distribution System
99
Transformers in distribution systems can be broadly categorized into distribution substation transformers and other distribution transformers. They are crucial for stepping down high transmission voltages to levels suitable for distribution and end-user applications.
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
99
Zones of Protection
151
In power systems, the entire setup is divided into protective zones to isolate faults and protect the rest of the network. These zones include generators, transformers, buses, transmission lines, distribution lines, and motors. Each zone can be visualized as a separate room in a house, with each room protected by its own circuit breaker.
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
151
Primary Distribution
97
Primary distribution systems deliver electrical power from substations to consumers through various voltage classes, with 15-kV class voltages being predominant among U.S. utilities. Older 2.5- and 5-kV classes are being replaced by 15-kV primaries, while higher 25- to 34.5-kV classes are used in high-density urban areas and rural regions with long feeders. Three-phase, four-wire multigrounded systems are widely employed for balanced power delivery, using the neutral wire as a grounding point.
97
Design Example: Identifying the Locations of Monuments in the Field Using Global Positioning System Device
26
Surveyors use Global Positioning System (GPS) technology to measure the precise location and elevation of points on Earth. In a recent survey, GPS receivers were used to determine the coordinates and elevations of two park monuments. The process involved careful mission planning, data collection, and correction to ensure accuracy. The survey began with mission planning to identify optimal satellite visibility and minimize Position Dilution of Precision (PDOP). A geodetic control point...
26


